Operation Manual

7-stage chargers are designed for indoor, out of weather use only. Ensure that
both charger and battery are in a well-ventilated space during charging.
The battery charger end plates include a mounting flange for easy mounting.
If permanently fixed the charger should be mounted to a suitable horizontal or
vertical panel, with at least 10cm clearance from the end plates to
provide adequate ventilation for the cooling fan.
3.5mm
mounting hole
13
14. MOUNTING INSTRUCTIONS
It is possible to hard wire the DC charging leads to the battery for permanent
installations.
You will need 2 x ring terminals, an inline fuse holder and a fuse with a rating
equal to or more than twice of the chargers output. (See below)
4A = 8 Amp fuse 12A = 25 Amp fuse
5A = 10 Amp fuse 15A = 30 Amp fuse
7A = 15 Amp fuse 20A = 40 Amp fuse
10A = 20 Amp fuse