AeGIS 8000 Series Installation and Programming Manual REV. 08.31.10 PACH & COMPANY www.pach-co.
TABLE OF CONTENTS Chapter 1. Getting Started ------------------------------------------------------------ 1 1.1 1.2 1.3 1.4 Introduction --------------------------------------------------------------------------- 1 System Description, specifications and accessories ---------------------- 1 Unpacking the system ------------------------------------------------------------- 2 Warranty ------------------------------------------------------------------------------ 3 Chapter 2.
LIMITATIONS OF LIABILITY This manual is subject to change without notice. Pach and Company is not liable for any errors that might occur from use of this document, nor is any commitment to update the information herein implied. Pach and Company does not assume any liability for any damages, which may arise in installation or use of the AeGIS 8000 Series. Pach and Company does not assume liability for any incompatibility between the AeGIS 8000 Series and users devices.
Chapter 1 GETTING STARTED 1.1 INTRODUCTION Pach & Company thanks and congratulates you on the purchase of your AeGIS 8000 Series Telephone Access Control Systems. The AeGIS 8000 Series are a dedicated Telephone Entry Access Control System, available in surface and full-flush mount. A mounting ring is required for full-flush mount. The manual is designed to guide you through the proper programming and use of the AeGIS 8000 Series. It is important for you to read and follow the manual completely.
Relay Output: Form C Dry Contact 120 VAC 10A/ 24VDC 10A/ 250VAC 7A Memory Type: EEPROM Tone Detection: Crystal controlled, capable of detecting short bursts 80 ms Mounting: Surface and Full-Flush, outdoor or indoor. Construction: 16 gauge cold rolled steel back box and brushed stainless steel or brushed brass plating faceplate.
1. The products must be properly installed as specified; and maintained or used as intended. 2. Cause of product failure is not due to vandalism or malicious mischief, improper installation, abnormal physical or electrical stress, lightning, power surges, misuse, negligence, accidents, or Natural disasters. 3.
NEW PRODUCT WARRANTY EXCEPTION WIEGAND CARD, KEYFOB AND TRANSMITTER Pach and Company warrants the wiegand card, clam, and keyfob to be free of defects in material or workmanship for a period of three (3) months from the date of invoice. The above warranty is subject to the following conditions. 1. The products must be properly installed as specified; and maintained or used as intended. 2.
3. Warranty is immediately null and void if the product has been altered, repaired, or modified without express written authorization from Pach and Company Technical Department, with such authorization given only to manufacturer approved dealer/installers. 4. Under no circumstances will Pach and Company honor warranty any product found to have been altered, repaired, and/or modified by the end-user consumer. 5.
shipped to Pach and Company repair center. 9. Pach and Company warranty does not guarantee any product, new or repaired, to be free of operation error or service interruption in any way during the course of daily product operation 10.
Chapter 2 INSTALLATION A proper installation of the AeGIS system is very essential. You MUST follow the installation procedures, block diagrams and installation requirements as specified in this chapter. 6 4 3 7 5 2 Heater Pad Thermostat 1 8 Figure 2.
1 GROUNDING Grounding the AeGIS 8000 System is essential. Please comply with all local ordinances and industry standard procedures to ensure a complete and safe ground. Recommended earth grounds are: • Use 16-gauge solid wire for grounding. • Installing a ground steel rod from the steel enclosure to the earth ground, use the same grounding point on all systems for best ground. • Installing a solid heavy gauge wire from the AeGIS steel enclosure to a water pipe.
5 POWER A 12 VAC 40VA transformer is supplied by Pach and Company. However, 12 VDC 40VA power supply can be used to power the AeGIS 8000 Series use the same connection as shown on figure 2.1. The DC output must be between 13.5 VDC-14.0 VDC, if the output is less than the range specified, the relay will not work and the door will not function properly. • Two conductors, 18-gauge wire. See installation instruction if ASP1 Surge Protector is used.
Chapter 3 PROGRAMMING The AeGIS 8000 Series can be programmed LOCAL via built-in keypad or REMOTE via modem (see Management Software Manual for remote programming). LOG ON TO PROGRAMMING MODE Two ways to log on to programming mode: Using a valid master code Step 1: PRESS 0 AND # SIMULTANEOUSLY THEN RELEASE, the display screen will stop scrolling. Repeat the process again if the display is still scrolling. Step 2: Enter the valid 4-digit master code (default master code is 0000).
FUNCTION CODE PROGRAMMING Step 2 Enter function code 00, then #, the display will show Master Code: 0000 Step 3 Enter a new 4-digit master code the press #, the display will show Select Func: _ _ or press * to cancel, the display will show ERROR DATA * * * * Disregard the message and the current master code will remain in the system. Step 4 Select another function code to continue programming or press * to exit programming mode and you will hear “three short beeps”.
FUNCTION CODE PROGRAMMING • • • • • • Press Press Press Press Press Press show 2 2 4 0 1 1 once times for letter A then press # three times for letter C then press # twice for letter H then press # for space then eleven times for 1 then press # twelve times for 2 then press ## then the display will PH #: _ _ _ _ _ _ _ _ _ _ _ Step 5 Enter the tenant phone number or extension number up to 11-digit then press #, the display will show ACCESS CODE:_ _ _ _ Step 6 Enter the 4-digit access code then press #.
FUNCTION CODE PROGRAMMING Access Code: current code Step 6 • To change the access code, press * then enter a new one then press #. • To keep the current access code, press # Step 7 Proceed to step 2 and select the same function code or different function code to continue programming or press * to exit the 03 DELETE AN EXISTING TENANT You must know the directory code to delete an existing tenant. Delete any unused directory to free the memory. programming mode and you will hear “ three short beeps”.
FUNCTION CODE PROGRAMMING 05 Step 1 Log on to programming mode, see instruction above. The display will show MANUAL UNLOCK AND LOCK RELAY 1 (DOOR 1) Select Func: _ _ Step 2 Enter function code 05 then press #, the display will show OPEN1:00 HOURS Step 3 Enter • 01-98 hours to unlock door 1 • 99 hours to unlock door 1 for indefinite time • 00 hours to lock door 1 then press # or * to cancel.
FUNCTION CODE 08 PROGRAMMING Not applicable, do not change the default setting. SYSTEM ID NUMBER (DEFAULT SETTING IS =1 ) 09 DIRECTORY DIGITS (DEFAULT SETTING IS=3) Step 1 Log on to programming mode, see instruction above. The display will show Select Func: _ _ Directory is used to identify a tenant name. It must be unique for every tenant.
FUNCTION CODE 11 OPEN RELAY 1 (DOOR 1) TIME INTERVAL (DEFAULT SETTING IS=12) The length of time relay 1 turns on. PROGRAMMING Step 1 Log on to programming mode, see instruction above. The display will show Select Func: _ _ Step 2 Enter function code 11 then press #, the display will show OPEN1 TIME: 12 Step 3 Enter 04-99 seconds then press #.
FUNCTION CODE PROGRAMMING Step 4 Proceed to step 2 and select the same function code or different function code to continue programming or press * to exit the 16 Step 1 Log on to programming mode, see instruction above. The display will show programming mode and you will hear “ three short beeps”. VERIFY THE CURRENT DATE Select Func: _ _ Step 2 Enter function code 16 then press #, the display will show the current date for about 3 seconds FRI JAN.
FUNCTION CODE PROGRAMMING 20 Step 1 Log on to programming mode, see instruction above. The display will show RELAY 1 (DOOR 1) REMOTE ACCESS NUMBER SELECTION (Default setting is 9) Select Func: _ _ Remote access number is used for all tenants to Step 2 Enter function code 20 then press #, the display will show provide remote access to their visitor(s). This number can be changed. The AeGIS 8000 OpenDoor1 No: 9 Series have two relay, the second relay remote access number is set for number 8.
FUNCTION CODE XXXX = Model Number then press # PROGRAMMING MM = Month DD = Date YY= Year Step 3 Proceed to step 2 and select the same function code or different function code to continue programming or press * to exit the 50 CLEAR THE MEMORY TO FACTORY DEFAULT programming mode and you will hear “ three short beeps”. Step 1 Log on to programming mode, see instruction above.
FUNCTION CODE PROGRAMMING • 1 = enable • 0 = disable then press # Step 3 Enter Step 4 Proceed to step 2 and select the same function code or different function code to continue programming or press * to exit the programming mode and you will hear “ three short beeps”. 72 LOCK-OUT COUNT (Default setting is 3) Step 1 Log on to programming mode, see instruction above.
FUNCTION CODE PROGRAMMING Step 1 Log on to programming mode, see instruction above.
FUNCTION CODE 78 VIEW A DIRECTORY CODE PROGRAMMING Step 1 Log on to programming mode, see instruction above. The display will show The tenant name must be available to view a directory code associated with the tenant. Select Func: _ _ Step 2 Enter function code 78 then press #, the display will show XXXXXXXXXXXXXXXX XX......= Name in alphabetical order.
Chapter 4 SYSTEM’S OPERATION TO VIEW A TENANT NAME 1. Press 3 to view from A-Z 2. Press 6 to view from Z-A TO INITIATE CALL AND UNLOCK THE DOOR Two ways to initiate a call: OR GATE 1. USING A SCROLLING ELECTRONIC DIRECTORY Step 1 Press 3 or 6 to scroll the tenant name, when the tenant name you are intended to call is visible on the display, then press # to initiate the call. The display will show WAIT. . .
TO USE 4-DIGIT PERSONAL ACCESS CODE Personal access code is used to unlock the door without using a key. TO CHECK THE TOTAL NUMBER OF TENANT Press * the the 4-digit access code. Step 1 Log on to programming mode, see instruction above. The display will show Select Func: _ _ Step 2 Press 91 then press #, the system will show the total number of tenant.
Chapter 5 TROUBLE SHOOTING GUIDE DISPLAY PROBLEMS SOLUTIONS AND SUGGESTIONS The display is blank. • Check system’s power, make sure is ON. The power LED2 must be ON. If the LED2 is OFF, check the power switch, it must be switched to the left for ON. • Check the fuse (1.5 A 250 Volt). • Check the input power (12.5 -13.5 VAC or 13.5 -14.5 VDC) • Check the LCD’s ribbon cable connections. The red line must be facing up. • Adjust the LCD intensity by turning (VR3) clockwise.
GATE PROBLEMS Remote access does not unlock the door or gate. SOLUTIONS AND SUGGESTIONS • Check the remote open door number to release the door or gate on function code 20 and 21. • Check if the problem occurs on all tenants. • If the display shows door open, check the system’s relay using an ohm meter. The meter should read a closed circuit across the RC1 and NO1 or RC2 and NO2 or open circuit across the RC1 and NC1 or RC2 and NC2.
GENERAL FCC REQUIREMENTS This equipment complies with Part 68 of the FCC rules. Located on the back of your AeGIS system is a label that contains, among other information, the FCC registration and ringer equivalence number (REN) for the system. Prior to installing your AeGIS system, please call your telephone company and provide them the FCC registration and REN numbers as well as the telephone number of the line to which you will connect the system.
AeGIS 8000 SERIES QUICK REFERENCE GUIDE LOCAL PROGRAMMING 1) PRESS 0 AND # SIMULTANEOUSLY THEN RELEASE, the display screen stops scrolling (If the display screen is still scrolling repeat this step again) then enter the valid 4-digit Master Code (default Master Code: 0000). Now, you are in programming mode and see table below to continue.