Owner manual

Form 1145 Mini Installation Form and Operation Manual 02/02/2006
7
G et ting Speed
G et ting Accel
At this point a servo feed ready for normal operation.
Units of measure are displayed in inches or meters/millimeters, depending on the value of the scale parameter.
Standard Scale values are: 4106.7 counts/inch and 161.7 counts/mm.
1 L en gt h:2. 54 in
2 S pe ed : 100 in/s
3 A cc el :400 in/s ^2
E nt er c hoic e:
1 L en gt h:25 .4 mm
2 S pe ed : 2.5 m/s
3 A cc el :10 m/s ^2
E nt er c hoic e:
To Change:
> Length press ‘1’ then ‘ENTER’
> Speed press ‘2’ then ‘ENTER’
> Accel press ‘3’ then ‘ENTER’
4.1 ENTER FEED LENGTH
Enter in ‘1’ and press ‘ENTER’.
1 L en gt h:2. 54 in
2 S pe ed : 100 in/s
3 A cc el :400 in/s^2
E nt er c hoic e:
Enter in the new feed Length and press ‘ENTER’ or to cancel, press ‘ENTER’ (leave the Length field blank).
L en gt h: 2.54 in
N ew L en gth:
P re ss E NTER to exit
L en gt h: 2.54 in
N ew L en gth: 3.00
P re sS E NTER to exit