Installation and Operating Instructions Owner's manual

STEP #1:
The ‘UNDERLINE’ type cursor is located under
the length display whenever this screen is called up.
This indicates that this entry is capable of being
modified.
STEP #2:
Enter a new feed length; for instance...1.253 inches.
Press the ‘
1’ key, press the ‘.’ Key, press the ‘2’ key,
press the ‘
5’ key, press the ‘3’ key, and press the
ENTER’ key. The control will now take a moment
to clear the existing length value in its memory and
then "memorize" the new setting. The display
should now show the new feed length setting. The
maximum feed length is limited to 8,388,608
encoder counts or 999.750 inches.
4.2 PROGRAM A NEW
BATCH COUNT
STEP #1
Position the ‘UNDERLINE’ type cursor under
C
OUNT. Use the key.
STEP #2
Enter a new desired batch count. For instance....
1000 pieces. Press the ‘
1’, ‘0’, ‘0’, ‘0’, and ‘ENTER
buttons. The control takes a moment to clear the
existing batch count setting in memory, and then
"memorizes" the new value. Enter a value of ‘
0’ to
disable the batch counter. The display should now
show:
6
After the first Index/Part is made, the display
will show:
4.3 PROGRAM A NEW SPEED
FOR THE FEED
STEP#1:
Position the ‘UNDERLINE
’ type cursor under
S
PEED with the key.
STEP #2:
Enter a new speed value, 60 inches per second is the
maximum speed setting. 1 inch per second is the
minimum speed setting.
We will use 50/inches per second as our
example... Press the ‘
5’, ‘0’, and ‘ENTER’ buttons.
The control clears the existing value and inserts
50/seconds into its memory.
The display should now show the new setting:
These (3) parameters may be changed when the
running batch is stopped. All other feeder
parameters are locked out of the editing mode via
RUN/PROGRAM’ switch located inside the
electrical enclosure on the panel.
LENGTH 00008.000
COUNT 100000
SPEED 0060/SEC
LENGTH 00001.253
COUNT 100000
SPEED 0060/SEC
LENGTH 00001.253
C
OUNT 100000
SPEED 0060/SEC
LENGTH 00001.253
C
OUNT 001000
SPEED 0060/SEC
LENGTH 00001.253
COUNT 001000
S
PEED 0060/SEC
LENGTH 00001.253
COUNT 001000
S
PEED 0060/SEC
000001 / 001000
LENGTH 00001.253
COUNT 001000
S
PEED 0050/SEC
5. OPERATING THE FEED
NOTE:
It is very important to remember that the motor
on the Magnum Servo Feed System is only
for feeding material. It is not intended to be the
power source for a pull-through straightening
device, or the like. An adequate free loop must
be provided at all times. This will assure
consistent and accurate feeding.
5.1 PRIORITY MODE
The Magnum Servo Roll Feed has (2) modes of
automatic cycle starting. The Operator can