Installation and Operating Instructions Owner's manual
19
Installation & Operating Manual
Programmable Limit Switch Job Set-Up
Typical Die Set-Up Chart
Die No. __________
Part No. _________
______ No. ______
Cam Function (Name) and Number “ON” Angle “OFF” Angle
#1 Feed Advance 235° 90°
#2 Continue Cam 180° 200°
#3 Pilot Release 150° 180°
#4
#5
#6
#7
#8
F
E
E
D
D
I
R
E
C
T
I
O
N
360°
0°
180°
Steel Coil Thickness
Mfg. Std. Inch Equiv. Metric Equiv. Dial
Gage No. for Steel Sheet mm Setting
– .2500 6.35 0063[5]
3 .2391 6.07 0060[7]
4 .2242 5.69 0056[9]
5 .2092 5.31 0053[1]
6 .1943 4.94 0049[4]
– .1875 4.76 0047[6]
7 .1793 4.55 0045[5]
8 .1644 4.18 0041[8]
9 .1495 3.80 0038[0]
10 .1345 3.42 0034[2]
11 .1196 3.04 0030[4]
12 .1046 2.66 0026[6]
13 .0897 2.28 0022[8]
14 .0747 1.90 0019[0]
15 .0673 1.71 0017[1]
16 .0598 1.52 0015[2]
17 .0538 1.37 0013[7]
18 .0478 1.21 0012[1]
19 .0418 1.06 0010[6]
20 .0359 0.91 0009[1]
21 .0329 0.84 0008[4]
22 .0299 0.76 0007[6]
23 .0269 0.68 0006[8]
24 .0239 0.61 0006[1]
25 .0209 0.53 0005[3]
26 .0179 0.45 0014[5]
27 .0164 0.42 0004[2]
28 .0149 0.38 0003[8]
29 .0135 0.34 0003[4]
30 .0120 0.30 0003[0]
Thickness Setting Chart
Continue Cam
180°-200°
Never Touch
Pilot
Release
150°-180°
90°
270°
Feed
Advance
Cam
235°-90°