User Manual

maximum amount of time that the following error
limit may be exceeded before executing an
emergency stop.
• SYSTEM RESET: This function clears all
parameters to the factory default conditions. No
program may be running,
RESET must be active
(press and hold the ‘POWER ON’ button), and
the ‘
PROG/RUN’ switch must be set to ‘PROG
position. Pressing ‘1’ while the cursor is on the
SYSTEM RESET line will result in a confirmation
screen being displayed. Pressing ‘
1’ a second
time will reset the parameters to the factory
default values and the power-up screen will be
displayed. Pressing any other key than ‘
1’ will
result in aborting the system reset.
4.1 PROGRAM A NEW FEED
LENGTH, COUNT, SPEED
To program a new feed pitch/length the program
must be stopped. This may be done by pressing the
POWER ON’ or the ‘CYCLE STOP’ button
(if the press is running). Press the ‘
OPERATOR
button to view the following screen:
STEP #1:
The "UNDERLINE" type cursor is located under
the length display whenever this screen is called up.
This indicates that this entry is capable of being
modified.
STEP #2:
Enter a new feed length; for instance...1.253 inches.
Press the ‘1’ key, press the ‘.’ Key, press the ‘2’ key,
press the ‘
5’ key, press the ‘3’ key, and press the
ENTER’ key. The control will now take a moment
to clear the existing length value in its memory and
then "memorize" the new setting. The display
should now show the new feed length setting. The
maximum feed length is limited to 8,388,608
encoder counts or 1,140 inches.
6
4.2 PROGRAM A NEW
BATCH COUNT
STEP #1
Position the ‘UNDERLINE’ type cursor under
COUNT. Use the key.
STEP #2
Enter a new desired batch count. For instance....
1000 pieces. Press the ‘
1’, ‘0’, ‘0’, ‘0’, and ‘ENTER
buttons. The control takes a moment to clear the
existing batch count setting in memory, and then
memorizes” the new value. Enter a value of ‘
0’ to
disable the batch counter. The display should now
show:
4.3 PROGRAM A NEW SPEED
FOR THE FEED
STEP#1:
Position the ‘UNDERLINE’ type cursor under
S
PEED with the
key.
STEP #2:
Enter a new speed value, 70 (or 54 for HD) inches
per second is the maximum speed setting. 1 inch
per second is the minimum speed setting.
We will use 50/inches per second as our
example... Press the ‘
5’, ‘0’, and ‘ENTER’ buttons.
The control clears the existing value and inserts
50/seconds into its memory.
L
ENGTH 00008.000
COUNT 100000
SPEED 0062/SEC
LENGTH 00001.253
COUNT 100000
SPEED 0062/SEC
LENGTH 00001.253
C
OUNT 100000
SPEED 0062/SEC
LENGTH 00001.253
C
OUNT 001000
SPEED 0062/SEC
LENGTH 00001.253
COUNT 001000
S
PEED 0062/SEC