User's Manual

P.G. TM0032FE
3 - 1
SECTION 3. INSTALLATION, OPERATING AND MAINTENANCE
INSTRUCTIONS
3.1 UNPACKING AND INSPECTION
The following checks are recommended after receipt of the equipment from shipping
agent:
1. Check for any external damage that could have occurred in transit. If damage is
found, report to the shipping agent and to the supplier immediately.
2. Check that all items on the packing slip are present. If any are missing, report to
the supplier immediately.
3. The standard A211 amplifiers all have been programmed at the factory with the
following settings.
DC Continuity: - J1 and J2 both connected for thru power.
Alarm options: - DC and RF engaged for both bands.
Alarm Code: - Consecutive numbers assigned.
(Check for duplication if two lots used)
Attenuation: - Set to zero attenuation in both bands
The external DC powered unit has been programmed with the following settings:
DC Continuity: - J1 and J2 DC blocked.
Alarm options: - DC and RF engaged for both bands.
Alarm Code: - Consecutive numbers assigned.
(Check for duplication if two lots used)
Attenuation: - Set to zero attenuation in both bands
It is suggested that known changes required to these settings be made on the
bench before the units are installed at the site. Consult section 4.0 for more
information on this task.