M68334 Rev. A Tel-Link PMP - Remote Terminal Installation & Maintenance Manual 10-3
STEP 7. The person located at the Remote IDU should connect the LSM to the IDU and display
the Demod table of the Remote Site Controller window. Locate and observe the
dem_Meas_Signal_Quality register value.
STEP 8. Secure the Remote antenna assembly to prevent movement of azimuth and elevation
settings when the maximum reading has bee obtained.
STEP 9. WIth the LSM still connected to the Remote IDU, set the odu_TxLevCtrlEn register to
Power_Ramp. This will enable automatic gain control of the Remote ODU.
STEP 10. Set rac_Commissioning_Complete register to Yes.
10.3 Terminal Commissioning
10.3.1 LED Functionality
The following steps will verify the functionality of the LEDs on the Remote IDU:
STEP 1. Verify the LEDs are in the following state:
STEP 2. Remove the IF Cable to the Remote IDU and verify the following LED state occurred:
SECTOR BOARDS GREEN LEDs RED LEDs
Sector ATM Controller Blinking Off
Modulator Blinking Off
ODU Mux Blinking Off
Demodulator Blinking Off
REMOTE BOARD GREEN LEDs RED LEDs
Remote IDU Blinking Off
BOARD GREEN LEDs RED LEDs
Remote IDU Blinking Blinking