10.0 Initial Terminal Configuration and Testing
Proper functioning of this command and response exchange verifies that the IDU’s Local Site Manager
(LSM) agent and other critical software components are present and operational. Refer to the Tel-Link PMP
Local Site Manager Users Manual M68331 for detailed information on LSM operations. From the PC, the
installer can use the Get and Set commands to communicate with the LSM agent in the IDU to program and
interrogate the IDU configuration. Completion of the configuration will ensure items are properly loaded.
10.1 Terminal Configuration
STEP 1. After applying power to the Remote IDU and ASMs, allow the unit to warm up for five
minutes.
STEP 2. Verify that the Remote IDU and ASMs have completed their self-test processes and
the LEDs on the front of each card are in an operational state. (Refer to Table 10-1).
Table 10-1 - Board LED Indications
BOARD LED COLOR INDICATION DESCRIPTION
Remote IDU Green
(Active)
Blinking OK
Off or Solid On Fault
Red
(Fault)
Solid on or
Blinking
Fault
Off OK
ATM Service
Module
Green
(Port)
Solid On Active and Configured
Off Not Configured
Red
(Port)
Solid On Inactive and Configured
Off Not Configured
Red
(Fault)
Solid On Fault
Off OK
Green
(Power)
Solid On OK
Off Off