M68334 Rev. A Tel-Link PMP - Remote Terminal Installation & Maintenance Manual 9-1
9.0 Remote Terminal Initial Power Application
9.1 AC Power Application
STEP 1. Ensure the AC power switch of the Remote ATM IDU and ASMs are in the OFF posi-
tion.
STEP 2. Plug the AC cord for the Remote ATM IDU and ASMs into the AC source.
STEP 3. Place the AC power switch on the Remote ATM IDU and ASMs in the ON position.
STEP 4. Verify power is applied to the chassis by viewing the LEDs on the front panel.
STEP 5. If the LEDs on the boards do not illuminate, remove the AC connector from the appro-
priate equipment and verify wiring and AC voltage.
9.2 DC Power Application
STEP 1. Ensure the DC connectors to the Remote ATM IDU and ASMs are not connected.
STEP 2. Verify the appropriately sized fuses are installed IAW procedures in section 8.3.
STEP 3. Plug in the DC connector into the DC Power Port of the Remote ATM IDU and ASMs.
STEP 4. Verify power is applied to the chassis by viewing the LEDs on the front panel.
STEP 5. If the LEDs on the boards do not illuminate, remove the DC connector from the appro-
priate equipment and verify wiring and voltage polarity.