Figure 8-1 - One Rack Unit Remote IDU AC Input (Rear View)
STEP 2. Ground the ASM chassis using the ground stud on the rear of the chassis (refer to Fig-
ure 8-2). Ground the ASM chassis by installing compression type lug and connecting
the lug to the rack frame vertical channel, or local grounding bar, by using 12 AWG (or
larger) copper wire. Remove any paint or oxidation from the surface of the equipment.
Figure 8-2 - ASM AC Input (Rear View)
STEP 3. Attach and secure grounding cable, in accordance with local code, from building
ground to the antenna assembly pole structure for proper ODU grounding.