Installation and Operation Manual
November 1999
M68334 Rev. A Tel-Link PMP - Remote Terminal Installation & Maintenance Manual 6-1
6.0 Remote ODU Installation
6.1 Introduction
This procedure provides instruction for installing a P-COM Tel-Link Point to Multipoint Remote ODU/
Antenna assembly.
6.2 Tools Required
Multiple vendors of antenna and mounting assemblies may be used to operate with the ODU. A listing of
tools necessary to install an antenna/mounting assembly, can be found in Vendor's Antenna Installation
Manual.
6.3 Materials Required
• Antenna/mounting assembly. This assembly typically includes all hardware needed to install
the antenna to the mount, and the mount to a pole.
• Outdoor Unit (ODU)
6.4 Step by Step Remote ODU/Antenna Installation Procedure
WARNING! Failure to follow installation procedures may result in damage to the ODU/Antenna and
render the radio unusable. Read through the entire procedure before attempting
installation. If there are any questions, please contact P-COM Technical Assistance Center
(TAC) at 1 (877) 674-3600.
STEP 1. Install the mounting bracket on the pole so that the flat face of the Antenna Mounting
Bracket is in line with the direction of the sector signal using the four pole interface
bolts (refer to Figure 6-1).
Figure 6-1 - Antenna Mounting Bracket
Reversible
Pole
Clamps
Antenna
Mounting
Bracket
Elevation
Adjust
Hole
Intended
Antenna
Direction