M68333 Rev. A Tel-Link PMP - Sector Terminal Installation & Maintenance Manual 11-5
11.3.2 Hot Swap/Redundancy Test
The following steps will demonstrate the “Hot Swap” and redundancy features of the Sector IDU. Boards
will become functional when inserted into a powered chassis. A functional redundant board automatically
replaces a simulated board failure with the time frame listed below:
NOTE: The Sector IDU Chassis shall be equipped with a non-redundant set of boards and has
achieved an operational state. A communications link between a Sector and Remote
Terminals shall be established with the Remote Terminal configured in a network loopback
state.
11.3.2.1 Sector ATM Controller (SAC)
STEP 1. Insert a SAC board into the secondary SAC slot and allow the SAC to undergo its self-
test functions. Verify the secondary SAC is configured as the spare unit.
STEP 2. Pull the primary SAC board.
STEP 3. Initiate a Get All command on the SAC Section. The SAC Chassis Window should
refresh with configuration parameters and the following will occur:
The redundant SAC board will show the configuration parameters of the “Failed” pri-
mary board.
The Red LED on the redundant SAC board will extinguish.
The link to the Remote Terminal will lose lock and then reacquire within 10 seconds
SECTOR IDU
BOARD
RECOVERY
TIME
Sector ATM Controller < 15 Seconds
Modulator < 15 Seconds
ODU Mux < 10 Seconds
Demodulator < 15 Seconds