8-10 M68333 Rev. A Tel-Link PMP - Sector Terminal Installation & Maintenance Manual
STEP 1. Terminate IF Cable ends with Type-N Male RF connectors
STEP 2. Connect one end of the RG-58 coaxial cable to the Primary Sector Chassis Interface
Port of the Expansion IDU chassis to the Primary Expansion Chassis Interface Port of
the Basic IDU chassis. Connect one end of the RG-58 coaxial cable to the Secondary
Sector Chassis Interface Port of the Expansion IDU chassis to the Secondary Expan-
sion Chassis Interface Port of the Basic IDU chassis.
STEP 3. Connect the Primary IFL cable to the Primary IFL Interface Port on the Sector IDU
STEP 4. Ensure a 90° Type-N Adapter is securely attached to the ODU Type-N female port
STEP 5. Connect the IF cable to the 90° Type-N Adapter of the ODU and apply Weatherproof-
ing sealant
STEP 6. Connect one end of the Primary UTP-5 cable to the Primary Expansion Chassis Ether-
net Interface Port of the Basic Chassis to the Primary Expansion Chassis Ethernet
Interface Port of the Expansion Chassis. Connect one end of the Secondary UTP-5
cable to the Primary Expansion Chassis Ethernet Interface Port of the Basic Chassis to
the Secondary Expansion Chassis Ethernet Interface Port of the Expansion Chassis.
8.3 IDU to NMS and CPE Cabling
8.3.1 Tools Required
Refer to Table 3-2 in Section 3.0 for applicable tools.
8.3.2 Material Required
Serial, straight-through, computer cable with DB-9 male/female connectors, 15-25 ft in length
8.3.3 NMS Cabling
STEP 1. Connect the NMS serial cable to the NMS Interface Port located in the rear of all IDU
chassis (refer to Figure 8-1 and Figure 8-2). Screw down the connector to the NMS
Interface Port to maintain secure connection.
STEP 2. Connect ATM Interface Port cables to customer supplied equipment, e.g., ATM Switch.