Installation and Operation Manual
November 1999
M68333 Rev. A Tel-Link PMP - Sector Terminal Installation & Maintenance Manual 8-1
8.0 Sector Terminal Wire and Cabling Installation
8.1 Introduction
This procedure provides instructions for wiring and cabling for the Sector IDU chassises, ODU Power Sup-
ply chassis and the ODU. The following shelf wiring is required for full system operations:
• IFL Cabling interconnect (IDU to ODU)
• Power Supply Cabling
• ODU Power Supply Cable (ODU Power Supply to the IDU)
• Grounding
• Expansion IDU chassis wiring (where applicable)
8.2 Ground, Power and Signal Wiring
8.2.1 Tools Required
Refer to Table 3-2 in Section 3.0 for applicable tools.
8.2.2 Material Required
• IFL cable (LMR-400 recommended)
• 90° Type-N Adapter
• RF connectors (Type-N)
• Weatherproofing sealant
• Outside Grounding Wire IAW local code
• 12 AWG Green Stranded Cable
• 12 AWG Compression Ring Lugs
• 16 AWG Twisted Pair Cable
• Power Cord (as applicable)