M68333 Rev. A Tel-Link PMP - Sector Terminal Installation & Maintenance Manual 8-1
8.0 Sector Terminal Wire and Cabling Installation
8.1 Introduction
This procedure provides instructions for wiring and cabling for the Sector IDU chassises, ODU Power Sup-
ply chassis and the ODU. The following shelf wiring is required for full system operations:
IFL Cabling interconnect (IDU to ODU)
Power Supply Cabling
ODU Power Supply Cable (ODU Power Supply to the IDU)
Grounding
Expansion IDU chassis wiring (where applicable)
8.2 Ground, Power and Signal Wiring
8.2.1 Tools Required
Refer to Table 3-2 in Section 3.0 for applicable tools.
8.2.2 Material Required
IFL cable (LMR-400 recommended)
90° Type-N Adapter
RF connectors (Type-N)
Weatherproofing sealant
Outside Grounding Wire IAW local code
12 AWG Green Stranded Cable
12 AWG Compression Ring Lugs
16 AWG Twisted Pair Cable
Power Cord (as applicable)