User Manual

FULLY EXTEND FRAME
as shown in Figures 1, 2 and 3; then flip extended frame over to upright position.
SET UP BED FRAME
Before you begin
Read all instructions thoroughly before beginning set up.
Select a level site clear of rocks, branches and other hard or sharp objects before
setting up bed frame.
Carefully read all warning tags and TO OPEN /CLOSE VALVE tag on air mattress.
Two people can easily setup this bed with air mattress in minutes.
Figure 1
Figure 2 Figure 3
INSTALL OR CHANGE BATTERIES
Unhook latch and open lid to battery compart-
ment. (Fig. 4 and 5)
Insert four D-cell batteries as shown. (Fig. 5)
Close lid and hook latch to secure.
AIR MATTRESS PUMP
Figure 5
Figure 4
INFLATE AIR MATTRESS IN COVER
Unfold the mattress and flatten all edges.
Put air mattress inside cover
Pull valve cap on mattress to open. (Fig. 6)
NOTE: Insert black one-way valve before filling.
Place medium diameter nozzle onto “INFLATE”
labeled outlet of air pump. (Fig. 7)
Insert filling nozzle into fully opened valve.
Switch on air pump and fill mattress to
desired firmness. DO NOT OVERFILL.
Turn off switch, remove air pump and im-
mediately insert valve cap.
Figure 6 Figure 7
Switch
Medium Filling Nozzle
Valve
INFLATE AIR MATTRESS IN COVER (continued)
NOTE: Make sure air valve on mattress is posi-
tioned at the open zippered end of mattress cover.
(Fig. 8)
IMPORTANT: Fasteners are located on the bottom
side of the cover.
Zip up mattress cover completely.
ATTACH AIR MATTRESS
Figure 8
Cover
Valve
ATTACH MATTRESS TO TOP OF FRAME
Align fasteners located on bottom of the mattress
cover and top of the bed frame. (Fig. 9)
Press down firmly on top of mattress at each
corner to secure.
Figure 9
Remove mattress from frame.
STORING AIR MATTRESS, FRAME & PUMP
DEFLATE AIR MATTRESS
Unzip mattress cover to access valve cap.
Pull valve cap to open and pull out the one-way black
valve. (Fig. 10)
NOTE: This will allow air to escape and start deflating
the mattress.
Place medium diameter nozzle onto “DEFLATE”
labeled outlet on top of the air pump. (Fig. 10)
Insert filling attachment into fully opened valve.
Turn on air pump switch and remove air until mattress
is completely flattened.
Remove mattress cover then fold to store.
Fold the mattress to store.
Figure 10
Switch
FOLD UP FRAME
Flip extended frame over to as shown in Figure 3.
Fold up legs in reverse order (Figures 2 and 1)
Place the frame, mattress and cover in carry case.
Remove batteries from air pump and place in carry case.