J962V Installation Manual

33
Figure 27. J962V*D Inducer & Venting Options
VIEW -A-
VIEW -C-
Plug
Plug
Plug
OPTION
4
VIEW -B-
OPTION
2
Plug
Plug
OPTION
5
Plug
Plug
DOWNFLOW - 1 PIPE OPTIONS
(B, C, & D WIDTH CABINETS ONLY)
COMBUSTION
AIR
FLUE PIPE
FLUE PIPE
COMBUSTION
AIR
Rubber
Grommet
See
VIEW A for drain line positions See VIEW B for drain line positions
See VIEW C for drain line positions
See VIEW C f
or drain line positions
FLUE PIPE
Rubber
Grommet
COMBUSTION AIR
Plug
Flange
Flange
See VIEW B for drain line positions
FLUE PIPE
Plug
Flange
COMBUSTION AIR
See VIEW A for drain line positions
Rubber
Grommet
Rubber
Grommet
DOWNFLOW - 2 PIPE OPTIONS
(B, C, & D WIDTH CABINETS ONLY)
Plug
COMBUSTION
AIR
FLUE PIPE
OPTION
3
OPTION
6
COMBUSTION AIR
PVC Trap
PVC Tee
Rubber
Grommet
FLUE PIPE
PVC Trap
PVC Tee
PVC Tee
PVC Trap
Rubber
Grommet
PVC Tee
PVC Trap
Field Supplied
Drain Line
Attached to
PVC Tr ap
(Do Not Tr ap)
Field Supplied Drain Line
Attached to PVC Tr ap
(Do Not Tr ap)
Collector Box Drain
(Factory Equipped)
See NOTE 3
Inline Drain
(Field Supplied)
See NOTES 3 & 4
Collector Box Drain
(Factory Equipped)
See NOTE 3
Collector Box Drain
(Factory Equipped)
See NOTE 3
Inline Drain
(Factory Supplied)
See NOTE 4
X
See
NOTE 5
X
See
NOTE 5
X
See
NOTE 5
X
See
NOTE 5
Inline Drain
(Factory Supplied)
OPTION
1
NOTES:
1. See Accessories section (page 16) for optional PVC Tee configurations and drainage options.
2. Drain line traps may be positioned inside or outside the cabinet.
3. All drain lines must be trapped with J-Trap or field supplied loop and drained externally from the cabinet.
4. Inline drain is required only if “X” is greater than 6 feet.
5. Horizontal piping from inducer to flue pipe must be sloped 1/4” per foot to ensure drainage to PVC trap.