Technical Data Sheet
16
J951X072CD5SAAA
(WITH 5-SPEED ECM MOTOR)
HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)
MODEL NAME/
HEATING INPUT
RETURN
AIR VIA:
MOTOR
SPEED
External Static Pressure (in. w.c.)
0.1 0.2 0.3 0.4 0.5
CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE
J951X072CD5SAAA
72,000 BTU/Hr
Bottom
5 - High*
4 - Alternate
3 - Med-High** 1,705 37 1,670 38 1,640 39 1,615 39 1,575 40
2 - Med-Low 1,445 44 1,405 45 1,365 46 1,330 48 1,295 49
1 - Low***
COOLING AIRFLOW (CFM)
MODEL NAME/
HEATING INPUT
RETURN
AIR VIA:
MOTOR
SPEED
External Static Pressure (in. w.c.)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
CFM CFM CFM CFM CFM CFM CFM CFM
J951X072CD5SAAA
72,000 BTU/Hr
Bottom
5 - High* 2,120 2,105 2,085 2,025 2,035 2,035 1,975 1,930
4 - Alternate 1,930 1,885 1,855 1,825 1,785 1,755 1,760 1,715
3 - Med-High** 1,705 1,670 1,640 1,615 1,575 1,540 1,500 1,460
2 - Med-Low 1,445 1,405 1,365 1,330 1,295 1,245 1,200 1,155
1 - Low*** 1,010 950 890 820 755 675 615 560
*NOTES:
1. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
2. Data is shown without filter.
3. Temperature rises in the table are approximate. Actual temperature rises may vary.
4. Individual cells shaded in gray indicate a temperature rise outside of the recommended range.
5. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode.
6. Unit ships with (4) speeds pre-wired. Use of the fifth speed will require changing the appropriate wires at the motor connection. Consult the
wiring diagram for more information.
* Factory Set Cool
** Factory Set Heat
*** Factory Set Circulation