Technical Data Sheet
10
J951X108DU5SAAA
(WITH 5-SPEED ECM MOTOR)
HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)
MODEL NAME/
HEATING INPUT
RETURN
AIR VIA:
MOTOR
SPEED
External Static Pressure (in. w.c.)
0.1 0.2 0.3 0.4 0.5
CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE
J951X108DU5SAAA
108,000 BTU/Hr
Bottom
5 - High*
4 - Med-High** 1,965 48 1,905 50 1,840 52 1,790 53 1,740 55
3 - Med-Low 1,685 56 1,620 59 1,560 61 1,500 63 1,435 66
2 - Alternate 1,500 63
1 - Low***
Side
5 - High*
4 - Med-High** 1,935 49 1,875 51 1,810 52 1,755 54 1,705 56
3 - Med-Low 1,660 57 1,595 60 1,525 62 1,465 65
2 - Alternate 1,455 65
1 - Low***
Side + Bottom
or 2 sides
5 - High*
4 - Med-High** 1,995 48 1,935 49 1,875 51 1,825 52 1,775 54
3 - Med-Low 1,705 56 1,640 58 1,590 60 1,535 62 1,470 65
2 - Alternate 1,545 61 1,460 65
1 - Low***
COOLING AIRFLOW (CFM)
MODEL NAME/
HEATING INPUT
RETURN
AIR VIA:
MOTOR
SPEED
External Static Pressure (in. w.c.)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
CFM CFM CFM CFM CFM CFM CFM CFM
J951X108DU5SAAA
108,000 BTU/Hr
Bottom
5 - High* 2,295 2,240 2,190 2,140 2,090 2,035 2,005 2,015
4 - Med-High** 1,965 1,905 1,840 1,790 1,740 1,680 1,650 1,610
3 - Med-Low 1,685 1,620 1,560 1,500 1,435 1,385 1,335 1,275
2 - Alternate 1,500 1,420 1,355 1,295 1,235 1,175 1,110 1,055
1 - Low*** 1,045 950 845 760 670 595 525 460
Side
5 - High* 2,260 2,210 2,160 2,110 2,060 2,010 1,980 1,990
4 - Med-High** 1,935 1,875 1,810 1,755 1,705 1,650 1,630 1,590
3 - Med-Low 1,660 1,595 1,525 1,465 1,400 1,350 1,295 1,230
2 - Alternate 1,455 1,380 1,310 1,250 1,190 1,130 1,060 1,005
1 - Low*** 1,030 920 820 735 640 580 500 440
Side + Bottom
or 2 sides
5 - High* 2,330 2,270 2,215 2,170 2,120 2,060 2,025 2,040
4 - Med-High** 1,995 1,935 1,875 1,825 1,775 1,715 1,670 1,630
3 - Med-Low 1,705 1,640 1,590 1,535 1,470 1,420 1,375 1,315
2 - Alternate 1,545 1,460 1,405 1,340 1,280 1,215 1,165 1,100
1 - Low*** 1,060 975 870 780 700 610 555 480
*NOTES:
1. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
2. Data is shown without filter.
3. Temperature rises in the table are approximate. Actual temperature rises may vary.
4. Individual cells shaded in gray indicate a temperature rise outside of the recommended range.
5. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode.
6. Unit ships with (4) speeds pre-wired. Use of the fifth speed will require changing the appropriate wires at the motor connection. Consult the
wiring diagram for more information.
* Factory Set Cool
** Factory Set Heat
*** Factory Set Circulation