User Manual
Table Of Contents
- I.General Safety Requirements
- II.Safety Terms and Signs
- III.PC Configuration Requirements
- IV.Communication Interface Introduction
- V.How to Communicate Device with PC
- VI.Operation Interface of PC Software
- VII.Device Operation
- i.how to set the probe compensation
- ii. how to set the vertical system from PC softwar
- iii. how to set the horizontal system from PC soft
- iv. how to set the trigger system from PC software
- v. how to set channel from PC software
- vi. how to use automatic measurement
- vii. how to set sampling mode
- viii. how to set built-in function generator
- ix. how to use cursor measurement
- x.how to set the display system
- xi.how to change utility setting
- xii.how to use main action button
- xiii.how to use LAN communication interface
- xiv.how to work WiFi with PC software
- VIII.Technical Specifications
- IX. Appendix
26
to measure current
It’s possible to measure current via certain unit conversion, the detailed operation is, to use probe to
measure the voltage drop across certain resistor.
Press "CH1" or "CH2" to choose target channel, then check "Measure Current On", via or to
set the A/V ratio (Amps/Volts ratio).
Amps/Volts ratio = 1/Resistor value.
vi. how to use automatic measurement
From Function menu, via , enter into "Measure" option.
When moving the mouse at the main display area, on the left, will appear, click it, the Measure menu
will hide; another click will show the Measure menu.
Automatic measurement available in 20 options under Measure menu. From the left-bottom of the main
display area, up to 8 measurement options could be accommodated.
All of 20 automatic measurement options go in Vpp, Vmax, Vmin, Vtop, Vbase, Vamp, Vavg, Vrms,
Overshoot, Preshoot, Frequency (abbreviated as “Freq”), Period, Rise Time, Fall Time, Delay A→B ,
Delay A→B , +Width, -Width, +Duty, -Duty.
The “Measure” option covers several useful functions -
Show All: When choosing Channel 1, or Channel 2 from "Show All", one window will be called out, to
show all of involved measurement values from Channel 1, or Channel 2.
Add measurement: Check CH1, or CH2, or both firstly, the measurement results will come in full details
at the left-bottom of the main display area. Provided any/all of the current 8 measurement options not the
required, another 8 measurement options possible to add for each channel. The new measurement
option(s) will replace the current one(s) in the order of first till last.
Note: The measurement results of both channels possible to come together.
Remove measurement: Uncheck certain measurement option (20 options in total) to remove it.