Instructions / Assembly
Precautionary Notes:
Before installing this product, check local building codes for their
roong and ventilation requirements. This vent is designed for new
or re-roong work over any properly built and supported wood roof
deck having adequate nail-holding capacity and a clean, smooth
surface.
The InFlow
®
Vent is designed for roof slopes 4:12 or greater. The
manufacturer will not be responsible for issues resulting from any
deviation from the recommended application instructions and the
following precautions:
Roof Deck
• Maximum 6" width and 25/32" minimum thickness wood sheathing
• Minimum 3/8" plywood sheathing or 7/16" OSB
• Sheathing spaced minimum 1/8" and decking spaced maximum 1/4"
• Check local building codes or decking recommended by APA
Installing Initial Courses of Shingles & Underlayment
Step 1: Starting at the eave’s edge and continuing up two courses
beyond the exterior wall beneath the roof, install shingles and
underlayment per manufacturer’s instructions. Nail the second
course of shingles 4 1/2" above the lower edge of this same shingle
course.
See Figure 1.
Ventilation
• Must comply with local building code requirements.
Fasteners
• The InFlow
®
Vent is packaged with 3" ring shank nails to be used
when installing the vent and any roong materials installed directly
on the vent.
• Follow roof covering manufacturer's guidelines and local code
requirements for all other fasteners.
Tools and materials required to install a
VentSure
®
InFlow
®
Vent:
• Utility knife • Tape measure
• Circular saw • Hammer
• 3" Hand Nails (provided with the vent) • Chalk line
• Underlayment/self-adhering membrane
• Starter and Roong Shingles
The following instructions are for installing the VentSure
®
InFlow
®
Vent up the
roof slope beyond the eave, where eave application is not possible or will not
allow proper intake ventilation into the attic space.
Important Note – Please review the following instructions thoroughly
before beginning your installation.
4
foot
STRIP
INFLOW
®
VENT
VENTSURE
®
OWENS CORNING ROOFING AND ASPHALT, LLC
ONE OWENS CORNING PARKWAY
TOLEDO, OHIO 43659
Copyright © 2014 Owens Corning. All Rights Reserved.
Pub. No. 10018103-C
Cutting the 1 1/2" Vent Slot Opening
Step 2: Chalk a line from rake edge to rake edge that is 5" above
the lower edge of the last course of shingles installed.
Step 3: Chalk an additional line, 1 1/2" above this line. These lines
will identify the top and bottom edges of the vent slot opening.
Step 4: Make marks on the roof 6" in from the gable end wall at
each rake edge. The marks will identify the ends of the vent slot
opening.
See Figure 2.
Installing the Vent
Step 6: Position the first InFlow
®
Vent flush with the rake edge,
aligning the vent so the alignment notch is even with the lower edge
of the last shingle course installed.
See Figure 4.
Note: The vent slot opening must stop 6" from chimneys, end walls,
vertical walls, or other obstructions, and a minimum of 24" from roof
valleys.
See Figure 3.
Step 5: Using a circular saw with the depth set to the thickness of
the roofing materials plus the roof deck, cut and remove all materials
from the area identified for the vent slot opening.
Note: To provide full ventilation, be sure to maintain at least 1" of
clearance between the attic insulation and the bottom of the roof
deck.
Figure 4
Step 7: Using the nails provided, hand-nail the InFlow
®
Vent in place
using the built-in nail holes. Continue installing vents flush with each
other from rake edge to rake edge. When installing the final vent,
cut the non-rake edge of the vent (if necessary), to ensure a
factory-finished edge is flush with the rake edge.
See Figure 5.
Step 9. Continue shingle system installation per manufacturer’s
specifications.
Note: A nail gun and standard roofing nails can be used to install
shingle courses above the InFlow
®
Vent, per manufacturer’s
specification.
For installation conditions which are not addressed by these
instructions, please contact us at 1-800-GET-PINK
®
(1-800-438-7465)
or visit www.owenscorning.com for further instructions.
Installing Remaining Shingles & Underlayment
Step 8: Once the InFlow
®
Vent is installed, install underlayment and
hand nail starter shingles and one course of roofing shingles on top of
the vent using the 3" nails provided. IMPORTANT: Do not cover
the InFlow
®
Vent’s top intake openings. This will allow air
intake through the top of the vent.
Note: Ensure all nails fully penetrate the wood deck and do not fall
within the vent slot opening. Consult your shingle manufacturer for
recommendations if needed.
See Figures 6 & 7.
Figure 7
Figure 3
Figure 6
Figure 2
Figure 5
Typical “Mid-Roof” InFlow
®
Vent Application
Exposed Rafters or Open Softs
Typical “Mid-Roof” InFlow
®
Vent Application
Conditioned Living Area to Unconditioned Porch
Figure 1
Gable endwall
location below
Nail last course
4 1/2" above this
shingle’s lower edge
Underlayment
Eave edge
Exterior wallGable end wall
Eave
overhang
below
Two full
courses
above eave
overhang
Underlayment
Hand nail shingle
on top of vent
Hand nail starter
Gable endwall
location below
6" minimum
inside gable
end wall
6"
min.
6"
min.
1 1/2"
Vent slot
opening
5" Lower edge
of shingle
to bottom
of slot
4 1/2" Lower edge
to shingle nail
Rake
overhang
Gable
end
wall
6"
24"
24" min. from valley
1 1/2" slot
Cut & remove
material
Last course of shingles
(Step #1)
Last shingle installed
(Step #1)
InFlow
®
Vent
Lower edge
of last
shingle
course
Vent
alignment
notch
Lower
edge of
last course
of shingles
1 1/2"
Vent slot
5"
To
bottom
of slot
4 1/2"
To last
shingle nail
1 1/2"
Vent slot
opening
Factory edge
Factory
edge
Install underlayment,
hand nail starter and
shingles on top of vent
Note:
For mid-roof,
do NOT cover
top intake
opening.
3" Nails provided
for shingle
over vent
3" Hand
nail
starter
AIR
AIR
AIR
Cut edge
InFlow
®
Vent
InFlow
®
Vent
top intake
Underlayment
Hand nail shingle
on top of vent
Hand nail starter
InFlow
®
Vent
top intake
Installation Instructions for
Mid-Roof Application
(See separate sheet for Eave Application)
Underlayment
1 1/2" Vent slot
Underlayment
1 1/2" Vent slot
www.owenscorning.com
1-800-GET-PINK
®
(1-800-438-7465)
(Exhaust ventilation)
(Exhaust ventilation)
Mid-Roof
InFlow
®
Vent
Mid-Roof
InFlow
®
Vent