Installation Instructions

THERMAFIBER, INC.
ONE OWENS CORNING PARKWAY
TOLEDO, OHIO, USA 43659
1800 GETPINK
®
www.thermafiber.com
1
Verified by ICC-ES to contain a minimum of 70% recycled content. See ICC-ES Evaluation
Report VAR-1025 at icc-es.org.
2
ASTM C 1138.
Pub. No. 10022787. Printed in U.S.A. March 2018.
THE PINK PANTHER™ & © 1964–2018 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved.
The color PINK is a registered trademark of Owens Corning.
© 2018 Owens Corning. All Rights Reserved. © 2018 Thermafiber, Inc. All Rights Reserved.
28D
Mineral Wool Insulation
www.thermafiber.com
Noise Control:
Interior Walls
1. Seal Air Leaks.
Seal air leaks in the wall. These include
electrical, plumbing and other services
through the bottom or top of the wall
entering attached floors & ceilings and
also services through walls entering
neighboring rooms.
1. Seal Air Leaks.
Seal air leaks in the floor/ceiling. These
include electrical, plumbing and other
services through the floor/ceiling entering
rooms and walls above or below.
2. Install Batts.
Install Thermafiber
®
Fire & Sound
Guard
®
insulation between studs. Where
necessary, cut to length & shape around
obstructions in the stud cavity filling
all voids.
2. Install Batts.
Install Thermafiber
®
Fire & Sound
Guard
®
insulation between studs. Where
necessary, cut to length & shape around
obstructions in the joist cavity. Ensure
insulation is flush with the underside
of floor/ceiling joists.
Upgrade: Additional layers of insulation can be
installed up to the thickness of the cavity to achieve
improved acoustical performance.
3. Wiring, Plumbing &
Services. Splice insulation for
electrical wiring and cut to shape around
plumbing, lighting & other services to
ensure a tight, secure fit.
5. Apply Wall Finish.
Apply drywall or other wall finish.
3. Wiring, Plumbing &
Services. Splice insulation for
electrical wiring and cut to shape around
plumbing, lighting & other services to
ensure a tight, secure fit.
5. Apply Ceiling Finish.
Apply drywall or other ceiling finish.
4. OPTIONAL - Install
Resilient Metal Channels.
For best acoustical performance,
install resilient metal channels across
studs to minimize sound energy passing
through studs.
Note: Resilient metal channels are not necessary
with light gauge metal stud walls.
4. Install Resilient Metal
Channels. For best acoustical
performance, install resilient metal
channels across joists to minimize sound
energy passing through studs.
Note: Resilient Channel is very important for floors
systems to minimize impact sounds from people
living above.
22B
Noise Control: Interior
Floors/Ceilings
3" thickness in wood or
steel stud applications
Use Fire & Sound Guard
®
Acoustic Insulation
3" thickness in wood or
steel stud applications
Use Fire & Sound Guard
®
Acoustic Insulation
Installation and
Safety Tips
Cut Thermafiber
®
with long serrated knife
Working Area
Ensure installation area is accessible
and easy to move around in. You will
need something sturdy to kneel or
walk on such as a plank or a sheet of
plywood when working in an attic.
Tools
Keep the following tools on hand:
serrated knife, safety glasses,
mask and gloves.
Safety First
Wear protective gear: goggles,
gloves, dust mask or respirator,
long pants and sleeves. Ensure
there’s proper lighting.
1. Measure & Cut
The insulation is easy to cut with a serrated
knife for custom fitting around electrical boxes,
pipes, duct-work, wiring, or between
non-standard studs and joist.
2. Squeeze & Insert
The insulation is flexible and pliable; simply
squeeze the sides to compress the insulation and
insert into the desired wall.
3. Release & Expand
Once in place, the insulation naturally expands
to fill in the space, creating a snug, custom fit.
28A 28B 28C
28A 28B 28C
28A 28B 28C