Product Specifications

Fiberglass-Based Asphalt Shingles & Accessories
3.5 LOW SLOPE ROOFING SYSTEM INSTALLATION
A. Install Owens Corning low slope roofing system in accordance with Owens Corning installation
instructions and in accordance with local building code requirements.
B. Owens Corning
low slope roofing system should only be installed on roofs with a slope of ¼:12 to
2:12.
C. Apply only when the weather is dry and the ambient temperature is 45°F (7°C) and rising. Do not
install when water in any form (i.e. rain, dew, ice, frost, snow) exist.
D. Apply only over clean, dry, dust-free surfaces
E. Ensure installation of DeckSeal MA NailBase does not prevent or interfere with ventilation of the
existing structure.
3.6 VENT INSTALLATION
A. Install Owens Corning™ vents in accordance with Owens Corning installation instructions and local
building code requirements.
B. Ventilation at minimum must meet or exceed local building code requirements. Owens Corning
recommends:
1. Net Free Ventilating Area (NFVA) of 1:150 as a minimum.
2. Balanced approach for most effective ventilation (balance between the lower and upper parts of
the roof by providing 50% of NFVA at the soffit and 50% at the ridge).
3. NFVA at the upper part of the roof should not exceed 50%.
4. Where length of the roof ridge is sufficient provide continuous ridge vents for most effective
ventilation approach.
3.7 PROTECTION
A. Protect installed products until completion of project.
B. Touch-up, repair or replace damaged products before Substantial Completion.
END OF SECTION