Product Specifications

Fiberglass-Based Asphalt Shingles & Accessories
3.5 LOW SLOPE ROOFING SYSTEM INSTALLATION
A. Install Owens Corning™ low slope roofing system in accordance with Owens Corning installation
instructions and in accordance with local building code requirements.
B. Owens Corning
™
low slope roofing system should only be installed on roofs with a slope of ¼:12 to
2:12.
C. Apply only when the weather is dry and the ambient temperature is 45°F (7°C) and rising. Do not
install when water in any form (i.e. rain, dew, ice, frost, snow) exist.
D. Apply only over clean, dry, dust-free surfaces
E. Ensure installation of DeckSeal MA NailBase does not prevent or interfere with ventilation of the
existing structure.
3.6 VENT INSTALLATION
A. Install Owens Corning™ vents in accordance with Owens Corning installation instructions and local
building code requirements.
B. Ventilation at minimum must meet or exceed local building code requirements. Owens Corning
recommends:
1. Net Free Ventilating Area (NFVA) of 1:150 as a minimum.
2. Balanced approach for most effective ventilation (balance between the lower and upper parts of
the roof by providing 50% of NFVA at the soffit and 50% at the ridge).
3. NFVA at the upper part of the roof should not exceed 50%.
4. Where length of the roof ridge is sufficient provide continuous ridge vents for most effective
ventilation approach.
3.7 PROTECTION
A. Protect installed products until completion of project.
B. Touch-up, repair or replace damaged products before Substantial Completion.
END OF SECTION