Installation Instructions

5
5
Línea de tiza horizontal
Horizontal chalk line
5
5
8
"
Fig. 5D
Aplicación de tejas
Shingle Application
Fourth Course
Cuarta hilera
Rake Edge
Borde de viga
inclinada
Trim
19
1
2
"
from left edge
Recortar
19
1
2
pulg. del borde izquierdo
19
1
2
"
Hilera 4
4th Course
Hiler
a 6
6th Cour
se
Hiler
a 5
5th Cour
se
Hiler
a 4
4th Cour
se
Hiler
a 3
3r
d Course
Hiler
a 2
2nd Cou
rse
Hiler
a 1
1st Cours
e
Self adhered membrane
Membrana autoadhesiva
Self adhered membrane
Membrana autoadhesiva
Self adhered membrane
Membrana autoadhesiva
Underlayment
Membrana de
impermeabilización
Aplicación de las tejas (cont.):
Cuarta hilera:
Quite 19
1
2 pulg. del borde izquierdo
de esta teja y aplique la pieza restante
sobre y por encima de la teja de la
tercera hilera y al ras del borde de
la tercera hilera, con 5
5
8 pulg. de
exposición. Consulte la Fig. 5D.
Sujete firmemente de acuerdo con las
instrucciones de sujeción.
Consulte la Fig. 4.
Quinta hilera:
Quite 26 pulg. del borde izquierdo
de esta teja y aplique la pieza restante
sobre y por encima de la teja de
la cuarta hilera y al ras del borde
de la cuarta hilera, con 5
5
8 pulg. de
exposición. Consulte la Fig. 5E.
Sujete firmemente de acuerdo con las
instrucciones de sujeción.
Consulte la Fig. 4.
Sexta hilera:
Quite 32
1
2 pulg. del borde izquierdo
de esta teja y aplique la pieza restante
sobre y por encima de la teja de
la quinta hilera y al ras del borde
de la quinta hilera, con 5
5
8 pulg. de
exposición. Consulte la Fig. 5F.
Sujete firmemente de acuerdo con las
instrucciones de sujeción.
Consulte la Fig. 4.
Hileras siguientes:
Para las hileras siguientes, repita los
pasos que se indican desde la primera
hasta la sexta hilera. Consulte la Fig. 5G.
5
Shingle Application (cont.):
Fourth Course:
Remove 19
1
2" from the left end of
this shingle and apply the remaining
piece over and above the third course
shingle and fl ush with edge of the third
course with 5
5
8" exposure. See Fig. 5D.
Fasten securely according to fastening
instructions. See Fig. 4.
Fifth Course:
Remove 26" from the left end of this
shingle and apply the remaining piece
over and above the fourth course
shingle and fl ush with edge of the
fourth course with 5
5
8" exposure.
See Fig. 5E.
Fasten securely according to fastening
instructions. See Fig. 4.
Sixth Course:
Remove 32
1
2" from the left end of this
shingle and apply the remaining piece
over and above the fifth course shingle
and fl ush with edge of the fifth course
with 5
5
8" exposure. See Fig. 5F.
Fasten securely according to fastening
instructions. See Fig. 4.
Succeeding Courses:
For succeeding courses, repeat first
through sixth course. See Fig. 5G.
Fig. 5F
Aplicación de tejas
Shingle Application
Sixth Course
Sexta hilera
Línea de tiza horizontal
Horizontal chalk line
5
5
8
"
Trim 32
1
2
" from left edge
Recortar
32
1
2
pulg. del borde izquierdo
32
1
2
"
Hilera 6
6th Course
Hiler
a 6
6th Cour
se
Hiler
a 5
5th Cour
se
Hiler
a 4
4th Cour
se
Hiler
a 3
3r
d Course
Hiler
a 2
2nd Cou
rse
Hiler
a 1
1st Cours
e
Self adhered membrane
Membrana autoadhesiva
Self adhered membrane
Membrana autoadhesiva
Self adhered membrane
Membrana autoadhesiva
Underlayment
Membrana de
impermeabilización