Specification
THIS IS NOT A CONSTRUCTION DOCUMENT. Edit carefully to coordinate with specific project requirements.
User must determine suitability of this guide specification in whole or in part for their particular project.
Owens Corning
®
Fiberglass Batt Insulation
Guide Specification 07 21 16 - 2
Next Gen™ Fiberglas™ Insulation Faced Batts and Rolls.
B.
Mock-Up: If requested, provide a mock-up of materials proposed for use for review of workmanship. Accepted
mock-ups may remain in place.
C.
Preconstruction Meeting: Convene a minimum of two weeks prior to commencing work of this section. Agenda shall
include materials proposed for use, sequence of construction and coordination with installation of adjacent and
covering materials
1.4 DELIVERY, STORAGE, AND HANDLING
A. Delivery: Deliver materials to the job site in original packages, containers, or bundles bearing the brand name and
manufacturer’s identification.
B. Storage: Store materials in dry locations with adequate ventilation, free from water, and in such a manner to permit
easy access for inspection and handling.
C. Handling: Handle using procedures recommended by the manufacturer for materials and personnel.
1.5 WARRANTY
A. Warranty: Provide manufacturer’s standard limited warranty against manufacturing defects.
PART 2 — PRODUCTS
2.1 MANUFACTURER
A. Thermal Insulation: PINK Next Gen™ Fiberglas™ Insulation by Owens Corning Insulating Systems, Toledo, OH
43659; www.owenscorning.com.
2.2 MATERIALS
A. PINK Next Gen™ Fiberglas™ Insulation Unfaced Batt Insulation: ASTM C 665, Type I, preformed formaldehyde
free glass fiber batt type, unfaced. Includes Unfaced PINK Next Gen™ Fiberglas™, Unfaced PINK Next Gen™
Fiberglas™ Sonobatts
®
Insulation and PINK Next Gen™ Fiberglas™ Sound Attenuation Batts (SAB) Insulation.
1. Noncombustible per ASTM E 136.
2. Flamespread less than 25, smoke developed less than 50 per ASTM E84.
3. ICC Building Code Construction Classification: All types.
4. Water vapor sorption, Maximum by weight: not more than 5 percent.
B. PINK Next Gen™ Fiberglas™ Insulation Kraft Faced Batt Insulation: ASTM C 665, Type II, Class C preformed
formaldehyde free glass fiber batt type, Kraft paper faced one side. Includes Kraft faced PINK Next Gen™
Fiberglas™ Insulation, Kraft faced PINK Next Gen™ Fiberglas™ Sonobatts
®
Insulation and PINK Next Gen™
Fiberglas™ Insulation ProPink FastBatt Insulation
1. ICC Building Code Construction Classification: III, IV, V.
2. Perm Rating: 1 perm maximum per ASTM E96.
C. PINK Next Gen™ Fiberglas™ Insulation Foil Faced Batt Insulation: ASTM C 665, Type III, Class C preformed
formaldehyde free glass fiber batt type, foil faced one side.
1. Flamespread less than 75, smoke developed less than 150 per ASTM E84.
2. ICC Building Code Construction Classification: III, IV, V.
3. Perm Rating: 0.5 perm maximum per ASTM E96.
D. PINK Next Gen™ Fiberglas™ Flame Spread 25 Insulation: ASTM C 665, Type II (PSK facing), Class A and
Type III (FSK facing), Class A preformed formaldehyde free glass fiber batt, poly/scrim/Kraft (PSK) or
foil/scrim/Kraft (FSK) faced on one side.
1. Flame spread less than 25, smoke developed index less than 50 per ASTM E84.
2. ICC building construction classification: all types.
3. Perm Rating: 0.5 maximum per ASTM E96.
E. Accessories: Provide accessories per insulating system manufacturer’s recommendations, including the following: