Use and Care Guide
PRODUCT DATA SHEET
EcoTouch
®
 PINK
®
Fiberglas
™
 Insulation
Description
Owens Corning
®
 EcoTouch
®
 PINK
®
 Fiberglas
™
 Insulation with 
PureFiber
®
 Technology is a preformed, fl exible blanket 
insulation. It is produced in R-values from 11 to 49, with 
thicknesses ranging from 3½   inches to 14 inches. It is available 
unfaced, or faced with either a kraft or foil vapor retarder.
Features
•  Excellent thermal control 
•  Effective acoustical control
•  Long term performance and will not settle nor slump 
within wall cavities
•  With less dust than other fi berglass products, EcoTouch
®
PINK
®
 Fiberglas
™
 insulation has excellent stiffness and 
recovery characteristics
1
•  Compression packaging from Owens Corning speeds job 
site handling and installation
1.  According to 2010 clinical trial conducted in Toronto, Canada by Ducker Worldwide on behalf 
of Owens Corning Insulation Systems, LLC.
Applications
•  Wood-framed wall, fl oor and roof/ceiling cavity wall 
assemblies
•  Metal-framed wall and fl oor cavity wall assemblies
•  Furring strips installed on the interior surface of basement 
walls
•  Interior surfaces of basement and unvented crawl space 
foundation walls
Standards, Codes Compliance 
•  Manufactured in compliance with ASTM C 665
•  Federal Specifi cation HH-I-521F has been canceled and 
is replaced by ASTM C 665
•  Classifi ed non-combustible when tested in accordance 
with ASTM E 136
•  Unfaced EcoTouch
®
 PINK
®
Fiberglas
™
 insulation is 
acceptable for use in ICC building construction types I 
through V; kraft and foil faced EcoTouch
®
 PINK
®
Fiberglas
™
 insulation are acceptable for use in ICC building 
construction types III, IV and V 
•  Certifi ed to meet California Code of Regulations, Title 
24, Chapter 12-13, Article 3, “Standards for Insulating 
Material”
Design Considerations
•  For optimum insulation performance the building thermal 
barrier (insulation) should be in continual alignment with 
the building air barrier. In framed cavities, the product 
thickness should match the depth of the framing members. 
•  Follow the local, applicable building code(s) to determine 
the need for and placement of a vapor retarder.
•  Do not install insulation on top, or within 3 inches of a 
recessed light fi xture unless the fi xture is labeled as 
“insulation contact” (IC) rated.
•  Kraft and standard foil facings will burn and cannot be left 
exposed. Install facings in substantial contact with the 
assembly fi nish material. Protect from open fl ame or other 
heat source. 
Installation
See Owens Corning publication “Installation Guide for 
Light Density Insulation” (Pub. No. 10017858) for more 
information. 
Physical Properties
Property (unit) Test Value
Thermal Resistance ASTM C518 See “Availability” table 
for R-values
Surface Burning Characteristics
2
(fl ame spread / smoke developed)
 Unfaced
 Kraft faced
 Foil faced
ASTM E 84 / UL 723
25 / 50
NR / NR
75 / 150
Critical Radiant Flux (W/cm
2
)ASTM E970  >0.12
Water Vapor Permeance (perms)
 Kraft faced
 Foil faced
ASTM E96
1.0
0.5
Water Vapor Sorption
(by weight)
ASTM C1104  <5%
Odor Emission ASTM C1304 Pass
Corrosion Resistance ASTM C665, part 13.8 Pass
Fungi Resistance ASTM C1338 Pass
2. The surface burning characteristics of EcoTouch
®
 Insulation were derived from products 
tested in accordance with ASTM E84. This standard is used solely to measure and describe 
properties of products in response to heat and fl ame under controlled laboratory conditions, 
and should not be used to describe or approve the fi re hazard of materials under actual fi re 
conditions. However, the results of these tests may be used as elements of a fi re risk assess-
ment that takes into account all of the factors pertinent to an assessment of the fi re hazard of 
a particular end use. Values are reported to the nearest fi ve rating.