Installation Instructions
Precautionary Note:
The manufacturer will not be responsible for
problems resulting from any deviation from the
recommended application instructions and the
following precautions:
CAUTION: Due to the aggressive nature of our
shingle sealant strip, please note the following: To
avoid shingles sticking in hot sun, do not have the
sealant strip make contact with various objects
on the roof, until you are ready to nail the shingle
in place.
Roof Top Loading: Lay shingle bundles at.
Do not bend over the ridge.
Roof Deck:
• 6" Maximum roof deck boards
• Minimum
3
⁄8" plywood
• Minimum
7
⁄16" OSB
Regardless of deck type used, the roo ng
installer must:
1. Install the deck material in strict compliance
with the deck manufacturer’s instructions.
2. Prevent the deck from getting wet before,
during and after installation.
Ventilation: Must meet or exceed FHA Minimum
Property Standards.
Handling: Use extra care in handling shingles
when the temperature is below 40°F.
Storage: Store in a covered ventilated area at a
maximum temperature of 110° F. Protect shingles
from weather when stored at the job site. Do not
store near steam pipes, radiators, etc.
Nails must be corrosion-resistant, 11- or
12-gauge, with heads at least
3
⁄8" in diameter.
Staples must be 16-gauge minimum,
15
⁄16" minimum
crown width and suf cient length to penetrate
¾ " into wood decking or through APA-rated roof
sheathing. Staples are to be corrosion protected.
All Fasteners must penetrate at least ¾ " into
the wood deck or completely through plywood
sheathing.
Notice: Owens Corning recommends the use
of nails as the preferred method of attaching
shingles to wood decking or other nailable
surface.
Specialty Eave Flashing: WeatherLock
®
underlayment or equivalent eave and ashing
membrane applied to a point at least 24" beyond
interior wall line. See Fig. 1.
Underlayment:
Standard slope (4" in 12" or more) Application
of underlayment, metal drip edges, and eaves
ashing. See Fig. 2.
Low slope (2" in 12" to less than 4" in 12")
Application of underlayment and metal drip
edges. See Fig 2A.
Fastener Placement: See Fig. 3.
Starter Course
Left Rake Application: Cut 35" off from the rst
bottom starter piece. Fasten the remaining 5" x
13
3
⁄8" to the deck as shown in Fig. 4, followed by
a full 13
3
⁄8" x 40” starter piece to the deck with 5
fasteners as shown.
Right Rake Application: Cut 5" off from the rst
bottom starter piece. Fasten the remaining 35" x
13
3
⁄8" to the deck as shown in Fig. 4A, followed by
a full 13
3
⁄8" x 40" starter piece to the deck with 5
fasteners as shown.
Note: Apply Woodcrest
®
/Woodmoor
®
shingles
after WoodStart
®
Starter Shingles are installed.
Apply Woodcrest
®
/Woodmoor
®
shingles per
the application instructions printed on the shingle
wrapper.
Made in U.S.A.
OWENS CORNING ROOFING AND ASPHALT, LLC
ONE OWENS CORNING PARKWAY
TOLEDO, OHIO, USA 43659
1
-
800
-
GET
-
PINK
®
w ww.roofing.owenscorning.com
Pub. No. 10011695. Printed in U.S.A. October 2009. THE PINK PANTHER
™
& ©
1964
–
2009 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved. The color
PINK is a registered trademark of Owens Corning. ©2009 Owens Corning.
Eaves ashing where required
Protector de aleros donde sea necesario
WeatherLock
WeatherLock
®
WeatherLock
®
Underlayment
Wall line
Línea de la pared
24" Beyond
interior wall line
24" más allá de la
línea de la pared interior
Deck
Cubierta
Slopes 4" in 12" or more
Pendientes de 4" en 12" o más
4" min. End lap
Traslape nal.
Mínimo 4"
Felt over drip edge at eave
Fieltro sobre el borde de
escurrimiento en el alero
Nails
Clavos
Drip edge
over felt at
rake edge
Reborde de
escurrimiento
sobre el eltro
en el borde
de caída
2"
Top lap
Traslape superior
de 2"
Vertical seams 6' min.
Costuras verticales.
6’ como mínimo
1 ½"
5"
1 ½"
40"
1 ¼" Nail Area
Área de clavos 1 ¼"
Nails
Clavos
13 8"
WoodStart
®
Starter Shingles
Installation Instructions
Figure 1
Specialty Eave Flashing
Figure 2
Underlayment Standard Slope
Slopes 2" in 12" to less than 4" in 12"
Pendientes 2" en 12" hasta menos de 4" en 12"
19"
19"
17"
36"
19"
First and succeeding courses
are 36" wide with 19" lap
El primero y los tendidos sucesivos son de
36" de ancho con traslape de 19"
Drip edge
Borde de escurrimiento
Drip edge
Borde de
escurrimiento
12" End lap
Traslape nal de 12"
Starter strip
Tira inicial
19"
Wall line
Línea de
la pared
Deck
Cubierta
Figure 2A
Underlayment Low Slope
Figure 3
Nail Pattern
5"
35"
40"
40"
Install rst strip
with 35" removed
Instaler primera
tira retirándole 35"
Asphalt saturated
felt underlayment
Refuerzo de eltro de
asfalto saturado
Starter strip is ush
with drip edges
Tira inicial al ras con los bordes
de escurrimiento
Nails located
in Nail Area
Clavos localizados
en el área de clavos
Drip edge
Borde de escurrimiento
Deck
Cubierta
Dripedge
Borde de
escurrimiento
Figure 4
Left Rake Application
5"
35"
40"
40"
Install rst strip
with 5" removed
Instaler primera
tira retirándole 5"
Asphalt saturated
felt underlayment
Refuerzo de eltro de
asfalto saturado
Starter strip is ush
with drip edges
Tira inicial al ras con los
bordes de escurrimiento
Nails located
in Nail Area
Clavos localizados
en el área de clavos
Drip edge
Borde de
escurrimiento
Deck
Cubierta
Drip
edge
Borde de
escurrimiento
Figure 4A
Right Rake Application