a. Utilize foil-faced Thermafiber
®
FireSpan
®
curtain wall Insulation with Thermafiber
®
Safing
insulation.
b. Apply approved smoke sealant in accordance with the third-party laboratory tested and listed
assembly.
c. Install safing insulation of proper density, thickness, compression, and orientation as prescribed
by the third-party laboratory listed and tested assembly.
d. Install safing insulation of proper density, thickness, and compression into poke-throughs and
penetrations as prescribed by the tested assembly.
5. Vapor Retarders:
a. Seal all seams in curtain wall insulation or exterior wall insulation with vapor retarder tape.
b. Application of vapor retarder must be directed by the architect or engineer of record.
c. For continuous vapor barrier, repair all tears in insulation foil-facing with vapor retarder tape.
3.3 PROTECTION
A. Protect installed products from damage due to harmful weather exposures, physical abuse, and other causes.
Provide temporary coverings or enclosures where insulation is subject to abuse and cannot be concealed and
protected by permanent construction immediately after installation.