ATTACHMENT AND SUPPORT
Installation of Mineral Wool Insulation
Z-Furring Channels with Owens Corning
®
Thermaber
®
Impasse
®
Hangers
Owens Corning
®

®
Impasse
®
Hangers attach directly to Z-Furring channels, eliminating any penetration of the water-resistive
barrier (WRB). Due to the “shelf” they provide, they are also much more effective at eliminating crushing of the panels on the bottom of
the structure. They can also be installed on the panels and then set into place, eliminating the need to pre-install impaling pins to the
structure, and then installing the insulation over the pins. This saves time during the installation.
Clip and Rail Systems
Owens Corning
®

®
RainBarrier
®
continuous insulation is compatible with virtually any cladding system in the industry,
including specialty thermally isolated clip and rail systems. These thermally isolated clips and systems reduce thermal bridging between
the cladding and the wall, improving the effective R-value of the insulation.
Thermally Isolated Clip and Rail Systems
CL-Talon
Knight Wall Systems
SMARTci GreenGir t
Strongwell STRONGIRT™
Z-Furring Channels with Impasse Hangers
Prior to insulation installation Post insulation installation