Instructions / Assembly

20
ATTACHMENT AND SUPPORT
Installation of Mineral Wool Insulation
Mineral wool insulation is installed between cladding attachments
QUANTITY OF FASTENERS
PER PANEL PANEL THICKNESS PANEL WIDTH PANEL LENGTH
4 1" to 4" 16" 48"
4 1" to 3" 24" 48"
5 4" 24" 48"
6 1" to 4" 36" 48" or 60"
Mineral wool insulation is installed between Z-Furring Channel
QUANTITY OF FASTENERS
PER PANEL PANEL THICKNESS PANEL WIDTH PANEL LENGTH
2 1" to 3" 16" 48"
2 1" to 2" 24" 48"
2 1" 36" 48" or 60"
3  16" 48"
3 3" to 4" 24" 48"
3  36" 48" or 60"
Notes:
Impaling pins may be installed prior to the air and water barrier.


Owens Corning
®

®
Impasse
®
Hangers are available in vertical and horizontal versions from 2” to 5” in 1/2” increments.
Custom sizes available.
Z-Furring Channel Layouts
Two-Fastener, Vertical Applications
Three-Fastener, Vertical Applications
Two-Fastener, Horizontal Applications
Three-Fastener, Horizontal Applications
Note: For horizontal applications, utilize furring channels with integral drainage capacity measured per ASTM E2273.
Insulation
Impaling Pin
Z-Furring
Channel
Z-Furring
Channel
Insulation
Impaling Pin
Z-Furring
Channel
Insulation
Impaling Pin
Z-Furring
Channel
Insulation
Impaling Pin