Instructions / Assembly
10
PRODUCT SELECTOR
Technical Data, Performance Attributes, and Attachment Methods
*
SEMI-RIGID PORTOLIO
PRODUCT TECHNICAL DATA
6
ACTUAL
DENSITY
“K” @ 75° [24°C]
BTU IN./HR. SQ. FT. °F
“R” VALUE
PER INCH OF
THICKNESS
7
“U” VALUE
PER INCH OF
THICKNESS
Owens Corning
®
®
RainBarrier
®
45 4.5 pcf 0.23 4.3 0.23
Owens Corning
®
®
RainBarrier
®
HD 6 pcf 0.23 4.3 0.23
Owens Corning
®
®
RainBarrier
®
vv™ 45 4.5 pcf 0.23 4.3 0.23
Owens Corning
®
®
RainBarrier
®
Dark™ HD 6 pcf 0.23 4.3 0.23
HIGH COMPRESSIVE PORTFOLIO
PRODUCT TECHNICAL DATA
6
COMPRESSIVE
STRENGTH
8
PSF “K” @ 75° [24°C]
BTU IN./HR. SQ.
FT. °F
“R” VALUE
PER INCH OF
THICKNESS
7
“U” VALUE
PER INCH OF
THICKNESS
Owens Corning
®
®
RainBarrier
®
ci High Compressive (80)
475 lbs./ft.² @ 10%
deformation
3 psi 0.24 4.2 0.24
Owens Corning
®
®
RainBarrier
®
ci High Compressive Plus (110)
720 lbs./ft.² @ 10%
deformation
5 psi 0.24 4.2 0.24
Owens Corning
®
®
RainBarrier
®
ci High Compressive Max
1,296 lbs./ft.² @
10% deformation
9 psi 0.24 4.2 0.24
6
Tested per ASTM C518, Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus, ASTM International.
7
R = product thickness divided by “k.”
8
Tested per ASTM C165, Standard Test Method for Measuring Compressive Properties of Thermal Insulations, ASTM International.
*Product data sheets are available at owenscorning.com/rainbarrier.