Generatorsareanintegralpartofmanyrenewableenergysystems.Settingagenerator’sstart
and stop times and voltage set points can be confusing. e following test helps assure your
generator is properly functioning and the programming is accurate (AGS must be set up rst in
order to perform this test).
Before any further programming, conrm that the generator is working properly by manually
turning it on and then shutting it o.
Advanced Generator Start (AGS) Test
eAGStestconrmstheAGSfunctionworksandthegeneratorhasbeenenabledduring
theAGSprogramming.SometimestheGENALERTsetpointsandpropertiesgetconfused
withAGSandthistestconrmsthecorrectsetpointsareused.GENALERTsetpoints
shouldnotbeusedasAGSsetpoints.esearetwoseparatemethodsforstartingagenerator
automatically.
Why do you might want it:IfQuiet Time Modeisset,theMATEwillnotallowmostAGS
settings to start the generator during the Quiet Time window. is is usually set up during
night time when a running generator would be an annoyance. Quiet Times can be set
individually for weekday and weekend, and consist of a Quiet Time Start and a Quiet Time Stop.
AswithGRID-USEsettings,ifyousettheSTARTandSTOPmodesforthesametime(for
example,12:00a.m.),eachwillbeignored.ToprogramQuiet Time Mode, go to the advanced
MATE menu.
PRESSTWICE:
• BringsuptheGENSTARTCONTROLscreen.
• Pressthe<ON> so key and wait for the
generator to go on.
• Pressthe<OFF> so key to shut the generator
o.
• Pressthe<AUTO> so key to put the generator
inAUTOmode
• Pressthe <OK>sokeytoreturntotheADV/
MATE/AGSscreen.
GEN START CONTROL
currently: AUTO
OFF AUTO ON OK
NOTE:e2-minute Voltagesetpoint(seepage86)willoverrideQuiet Time settings. is is
necessary to prevent the battery from falling below an unacceptable voltage.
Quiet Time