Installation Guide

62
ADV/MATE/PG4---------------
FN-DC advanced grid
tie authority
PG3 MODE ADV MAIN
ADV/MATE/PG3------------------------
advanced charger
oat control
PG2 CC FN-DC PG4
Pressing the <FN-DC> so key brings up the
FLEXnetDCcharge termination screen.
Pressing the <YES> so key enables the
(FLEXnet)FN-DC charge termination.eFN-
DC determines the batteries are fully charged
when Charge parms met is satised. e MATE
then commands all inverters and charge control-
lers to terminate their charge cycle.Pressing the
<NO> sokeydisablestheFN-DC charge termi-
nation. Press the <PG3> so key to return to the
previous screen.
Press the <PG4>sokeytoadvancetothenext
ADVscreen.
e FN-DC advanced grid tie authority screen
leadstoscreensallowingtheFN-DClimited
controlovertheGTFX(grid-tieinverter/charger).
Pressing the <MODE> so key leads to those
controls—disabled or Charge parms met. is is
thelastMATEADVFN-DCscreen.
InCharge parms met mode,theFN-DCdetemines
if the batteries are fully charged, signaling the
MATEtoenabletheMasterGTFXtosellpowerto
thegrid(theGTFXmustbegridtiemodeenabled
rst).Atmidnighteveryday,theMATEdisables
theGTFX’sgrid-tiemode.Whenarenewableen-
ergy source is available later during daylight hours
and the batteries are charged, sell mode returns.
Pressing the <INC> or <DEC> so keys toggles
the mode between Charge parms met and disabled,
which shuts o FN-DC gridtie enable.
ADV/MATE/PG3/FN-DC---------
enable FN-DC charge
termination: Yes
PG3 YES NO ADV
ADV/MATE/PG3------------------
advanced charger
oat control
PG2 CC FN-DC PG4
ADV/MATE/PG4/MODE----
FN-DC gridtie enable
disabled
PG4 INC DEC ADV
ADV/MATE/PG4/MODE----
FN-DC gridtie enable
Charge parms met
PG4 INC DEC ADV
FLEXnet DC*
*Please see the FLEXnet DC User’s Guide for
all related MATE screens.