Installation Guide
48
OUTBACK CHARGE CONTROLLER STATUS MODE Screens
ToviewtheCCSTATUSscreens,returntotheMAINMenu,pressthe<STATUS> so key and then choose
theCContheSTATUSchooseproductscreen.eSTATUSscreensincludeMODE,METER,andSET(SET
POINT).InSTATUSMode,theseChargeControllerfunctionscanbeviewedbytheMATE,butnotchanged.
MAIN--------------------------------
12:00:30P
SUM STATUS SETUP ADV
STATUS/CC/PAGE1------------------
MODE METER SETP MAIN
STATUS-------------------------------
choose device:
FX CC DC MAIN
STATUS/CC/MODE-------------P00
charger mode: Silent
DOWN STATUS PORT
STATUS/CC/MODE------------P00
aux relay state: ON
DOWN UP TOP PORT
STATUS/CC/MODE-------------P00
aux relay mode:
Low Batt
DOWN UP TOP PORT
STATUS/CC/MODE-----------------
end of mode menu
UP TOP STATUS
STATUS/CC/PAGE 1-----------------
MODE METER SETP PG2
Press <METER> to view
theCCMETERscreens.
CHARGE CONTROLLER MODE Screens
• charger mode:displaysoneofvechargingstages(Bulk,Absorption,Float,Silent,orEqualization)
• aux relay mode:displaysoneofeightChargeControllerAUXmodes(VentFan,PVTrigger,ERROR
OUTPUT,NightLight,Float,Diversion:Relay,Diversion:SolidSt,LowBatt(ery)Disconnect,or
Remote)
• aux relay state:indicatesiftheAUXisONorOFF
NOTE:All OutBack Charge Controller screens are displayed as CC screens on a MATE with
sowarecoderevision4.02andhigher.