Installation Guide

45
FX STATUS ERROR Screens
STATUS/FX/PAGE1-------------------
choose category:
MODES METER BATT PG2
STATUS/FX/ERROR-----------P00
low ac output No
voltage
DOWN STATUS PORT
STATUS/FX/PAGE2-------------------
choose category:
PG1 ERROR WARN PG3
STATUS/FX/ERROR----------P00
stacking No
error detected
DOWN UP TOP PORT
STATUS/FX/ERROR----------P00
low battery No
voltage
DOWN UP TOP PORT
STATUS/FX/ERROR----------P00
inverter No
overtemp
DOWN UP TOP PORT
STATUS/FX/ERROR----------P00
phase loss No
error
DOWN UP TOP PORT
STATUS/FX/ERROR----------P00
ac output No
shorted
DOWN UP TOP PORT
STATUS/FX/ERROR----------P00
high battery No
voltage
DOWN UP TOP PORT
STATUS/FX/ERROR---P00 ac output
ac output
backfeed
DOWN UP TOP PORT
STATUS/FX/PAGE2-----------------
choose category:
PG1 ERROR WARN PG3
STATUS/FX/ERROR------------------
end of error menu
UP TOP STATUS
Push <STAT> to return to the “choose
category”STATUS/FX/PAGE2
Push <WARN> to see
theWARN(ING)Menu.
ERROR Screens
• low ac output voltage: inverter could not supply enough AC voltage to meet demand
• stacking error detected:communicationproblemamongstackedFXs
• inverter overtemp:FXhasreacheditsmaximumallowedoperatingtemperature
• low battery voltage:batteryvoltageisbelowtheLOWBATTERYCUT-OUTVOLTAGEsetpoint(thisisa
commonerrorandwilllightupevenwithlowACoutorACshorted)
• phase loss error: not operational
• high battery voltage:batteryvoltageroseabovethesafehighbatteryvoltagelevelfor10seconds
• ac output shorted:inverterreacheditsmaximumcurrentandshutdown
• ac output backfeed:usuallyindicatesanotherACpowersourcewasconnectedtotheFX’sACoutput
ERRORscreenscanonlydisplayerrors;theydonotoeranymeanstocorrectthem.esearehardfaults.
eLEDissolidandtheinvertermustbeturnedoandthenontoreset.