Installation Manual and Specifications

Assembly
900-0123-01-01 Rev A
23
Assembling DC Positive (+) Cable Plate
(Bus Bar)
NOTE
: These instructions are not used with models GSLC175PV1-120/240, GSLC175PV1-
230, GSLC-PV1-300VDC, or GSLCPV1-300VDC-230. If using any of these models, proceed to
page 24 or the next appropriate instruction.
Figure
18
Assembling the DC Positive (+) Cable Plate
The bottom of each DC disconnect (circuit breaker)
is bolted to a metal plate (bus bar) which receives
the inverter’s positive (+) battery cables.
To assemble the DC Positive Plate:
1. Remove the nuts and other hardware
(washer, lock washer, hex nut) from
the bottom terminal in the back of
each DC disconnect.
2.
Place the two DC disconnects side by si
de.
3. Orient the DC positive plate so that the three
largest holes are at the top. These holes have a
diameter of 0.50" (1.3 cm). Insert the studs on
each disconnect through the first and third holes.
4. Replace the disconnect hardware
(washer, lock washer, hex nut).
Tighten the nuts to the values shown
in Table 1 on page 22. The plate will
hold the two circuit breakers together
as a set.