Product Manual
Specifications
900-0198-01-00 Rev A 47
Regulatory Specifications
Listings
This product carries a listing report by ETL. It is listed to the following standards:
UL 458 — Standard for Safety Power Converters/Inverters and Power Converter/Inverter Systems
for Land Vehicles and Marine Crafts, ANSI/UL 458, Ed:3, dated 2006/04/19 (with revisions through
and including 2013/02/20)
CSA C22.2, General Use Power Supplies, No. 107.1, Issue2001/09/01, Ed:3 (R2011)
Summary of Operating Limits
Severe conditions cause the inverter to limit its output or shut down for protection. The most common
conditions are high voltage, low voltage, and temperature. The limits for these conditions are
summarized in Table 16. See page 40 for more information on these conditions and the warning or error
messages which accompany them.
Table 16 Operating Limits for Mobile Models
Voltage Limits
12-Volt
Model
24-Volt
Model
32-Volt
Model
36-Volt
Model
48-Volt
Model
Limit Adjustable Off On Off On Off On Off On Off On
High Battery No
>17
Vdc
<17
Vdc
>34
Vdc
<34
Vdc
>45.3
Vdc
<45.3
Vdc
>51
Vdc
<51
Vdc
>68
Vdc
<68
Vdc
Low Battery (default) Yes
>10.5
Vdc
<12.5
Vdc
>21.0
Vdc
<25.0
Vdc
>28
Vdc
<33.3
Vdc
>31.5
Vdc
<37.5
Vdc
>42.0
Vdc
<50.0
Vdc
Temperature Limits
Limit
Transformer Output FETs Capacitors
Over Temperature
error
<125°C >125°C <95°C >95°C <95°C >95°C
Reduced charging >120°C >90°C >90°C
Internal Fan
<50°C >60°C <50°C >60°C <50°C >60°C