FP3 VFXR3648A-01 w/ FM80 FLEXpower THREE Specifications
2
OutBack reserves the right to make changes to the products and information contained in this document without notice.
Copyright © 2017 OutBack Power. All Rights Reserved. OutBack is a registered trademark of The Alpha Group.
FLEXpower THREE SPECIFICATIONS 04/2017
Details
FLEXpower THREE FXR
Finished Dimensions H x W x D (in/cm)
46.0 x 58.425 x 13.0 / 116.84 x 148.40 x 33.02
Weight (lb/kg)
433 / 196
*FLEXpower THREE FXR systems include a mounting bracket, three FXR/VFXR inverter/chargers, three FLEXmax charge controllers, MATE3, HUB10.3, FLEXnet DC, FLEXware surge protector, AC and DC wiring boxes, battery and PV array breakers, PV GFDI,
Input-Output-Bypass assembly, mounting locations for GFCI outlets and additional AC breakers.
** Overcurrent protective device.
3.6kVA 3.6kW 3.6kVA
3.06kW
Power Rating Notes
Inverters that specify power in VA but do not use the
unity standard Power Factor (PF) could have misleading
power specications. Volt-Amps (VA) is a total inverter
output, while Watts (W) represent the power consumed by the
electrical loads. PF, which varies by types of loads, is the ratio
of W to VA, and the dierence between the two is power in the
circuit that does no useful work. At 1.0PF (unity), all power is
used. This is the industry-standard used by OutBack Power.
VFXR3648A Power Factor Chart
Power Factor
1.0
0.75
0.5
0.25
0.0
Industry-Standard Non-Industry Standard
0.85
VFXR3648A Power Rating Chart
Power (VA)
8000
6000
4000
2000
0
100ms 5 sec 30 min continuous
Instantaneous Power Rating
Most stringent, massive load start VFXR3648A: 6000VA
Surge Power Rating
Less stringent load start VFXR3648A: 5400VA
Peak Power Rating
Frequent “heavy duty” load requirements VFXR3648A: 4000VA
Continuous Power Rating
Sustained “real world” load requirements VFXR3648A: 3600VA
6000VA
5400VA
4000VA
3600VA
Typical Eciency Rating
Real world eciency with variable loads VFXR3648A: 93%
CEC Eciency Rating
Most stringent US rating VFXR3648A: 91%
VFXR3648A Eciency Rating Chart
Eciency
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
1kVA 2kVA 3kVA 4kVA
91% (CEC)
93% (Typical)
INVERTING SELLING
For North America
Description Inverter(s) FW-X240 Bypass Charge Controller Inverter OCPD
**
PV OCPD
**
RTS
FP3 FXR3048A
Triple FXR3048A 9.0kW FLEXpower THREE FXR3048A (3x) — 208VAC Bypass FLEXmax 80 (3x) 175A 80A Ye s
FP3 VFXR3648A
Triple VFXR3648A, 10.3kW FLEXpower THREE VFXR3648A (3x) — 208VAC Bypass FLEXmax 80 (3x) 175A 80A Ye s
For Europe
Description Inverter(s) FW-X240 Bypass Charge Controller Inverter OCPD
**
PV OCPD
**
RTS
FP3 VFXR3048E
Triple VFXR3048E 9.0kW FLEXpower THREE VFXR3048E (3x) — 240VAC Bypass FLEXmax 80 (3x) 175A 80A Ye s
FP3 VFXR3024E
Triple VFXR3024E 9.0kW FLEXpower THREE VFXR3024E (3x) — 240VAC Bypass FLEXmax 80 (3x) 250A 80A Ye s
FP3 FXR2024E
Triple FXR2024E 6.0kW FLEXpower THREE FXR2024E (3x) — 240VAC Bypass FLEXmax 80 (3x) 175A 80A Ye s
VFXR3048E Power Factor Chart
Power Factor
VFXR3048E Eciency Rating Chart
Eciency
3.0kVA 3.0kW 3.0kVA
2.55kW
Power Rating Notes
Inverters that specify power in VA but do not use the
unity standard Power Factor (PF) could have misleading
power specications. Volt-Amps (VA) is a total inverter
output, while Watts (W) represent the power consumed by the
electrical loads. PF, which varies by types of loads, is the ratio
of W to VA, and the dierence between the two is power in the
circuit that does no useful work. At 1.0PF (unity), all power is
used. This is the industry-standard used by OutBack Power.
1.0
0.75
0.5
0.25
0.0
Industry-Standard Non-Industry Standard
0.85
VFXR3048E Power Rating Chart
Power (VA)
8000
6000
4000
2000
0
100ms 5 sec 30 min continuous
Instantaneous Power Rating
Most stringent, massive load start VFXR3048E: 5750VA
Surge Power Rating
Less stringent load start VFXR3048E: 5175VA
Peak Power Rating
Frequent “heavy duty” load requirements VFXR3048E: 3300VA
Continuous Power Rating
Sustained “real world” load requirements VFXR3048E: 3000VA
5750VA
5175VA
3300VA
3000VA
Typical Eciency Rating
Real world eciency with variable loads VFXR3048E: 93%
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
1kVA 2kVA 3kVA 4kVA
93% (Typical)
INVERTING SELLING