FN-DC Specications
Battery Voltage Input Range 8.0 to 80.0 Volts DC
Battery Voltage Resolution 0.1 Volts DC
Number of Current Channels One to Three (each can be a Source or Load)
Current Range (Each Channel) -1000.0 Amps to +1000.0 Amps DC
Current Resolution 0.1 Amps DC
State of Charge Display 0 to 100% (1% increments)
Aux Relay Configuration SPST, Magnetic Latching Relay
Aux Relay Max Rating 5 Amps @ 30 Volts DC
Current Shunt Type (order separately) 500 Amp / 50mv
Display Primary OutBack Power MATE or MATE2 4 x 20 LCD
Secondary Five LED Indicators on front of FLEXnet DC
Battery AH Capacity Range 100 to 10,000 Amp Hours
Data Logging Memory Most recent 128 Days
Programmable AUX Relay Settings Battery Volts Adjustable from 8.0 to 80.0 VDC
State of Charge Adjustable from 0 to 100%
Time Delay Adjustable from 0 to 240 Minutes
Accuracy 0.5% of Reading +/- 2 LSDs per channel
Operating Temperature Range 0 - 50
º
C
Mounting 3/4” Panel Mount Breaker Slot or Surface Mount
Warranty Standard 2 year
Weight Unit 5 oz. (.142kg)
Shipping 2 lbs. (.907 kg)
Dimensions (H x W x L) Unit 0.74 x 3.72 x 6.60” (1.88 x 9.45 x 16.75 cm)
Shipping 2.13 x 9 x 11.5” (5.4 x 22.86 x 29.21 cm)
European Ofce:
Barcelona, ESPAÑA
Phone: (+34) 600.843.845
www.outbackpower.com
Additional Available Data
• Total Battery Amps
• Averaged Battery Amps
• Averaged Battery Volts
• DC Amp-Hours IN Per Shunt
• DC Amp-Hours OUT Per Shunt
• DC kWh IN Per Shunt
• DC kWh OUT Per Shunt
• Last Cycle Amp Hours
• Last Cycle Watt Hours
• Last Cycle Amp Hour Charge Factor
• Last Cycle Watt Hour Charge Eciency
• Total Number of Days Full
• Cumulative Battery Amp Hours Removed