Outback FM80 User Manual

900-0009-01-00 Rev D 95
Specifications
Electrical and Mechanical Specifications
Specification FLEXmax 60 FLEXmax 80
Output Current Rating
@ 40°C ambient
60 amps continuous 80 amps continuous
Nominal Battery System Voltage 12, 24, 36, 48 or 60 Vdc (adjustable)
PV Open Circuit Voltage (V
oc
) 150 Vdc maximum (ETL Rating for UL1741 Standard);
145 Vdc temperature corrected V
oc
(operational maximum)
Standby Power Consumption Less than 1 watt typical
Charge Cycle Three-stage
Voltage Regulation Set Points 13-80 Vdc
Temperature Compensation 5 mV per °C per 2 V cell (with optional RTS)
PV Input Capability Down convert from any acceptable array voltage to any battery voltage.
Examples: 72 Vdc array to 24 Vdc battery; 60 Vdc array to 48 Vdc battery
Digital Display 4-line, 20-character per line backlit LCD display
Remote Interface RJ45 modular connector Cat 5 cable 8 wire
Operating Temperature Range –40° to 60°C (automatically derated above 40°C)
Conduit Knockouts One 1” on the back; one 1” on the left side; two 1” on the bottom
Warranty Five years parts and labor
Dimensions 13.5” H × 5.75” W × 4” D 16.25” H × 5.75” W × 4”D
Shipping Dimensions 18” H × 11” W × 8” D 21” H × 10.5” W × 9.75”D
Weight 11.6 lb (14 lb boxed) 12.20 lb (15.75 lb boxed)
Options RTS, HUB 4, HUB 10, MATE, MATE2, MATE3, MATE3s
Menu Languages English and Spanish
Firmware Revision
This manual applies to FLEXmax 80 or FLEXmax 60 charge controllers with a firmware revision
of 003.003.000 or higher.
Regulatory Specifications
Table 3 Regulatory Specifications for All Models
UL 1741 2nd Edition
CSA C22.2 No. 107.1-01
IEC 62509:2010