Outback FM80 User Manual
Operation
60 900-0009-01-00 Rev D
Rebooting the FLEXmax
If the screen becomes garbled or the FLEXmax controller otherwise will not respond to
commands, it may be necessary to reboot its internal processor.
IMPORTANT:
Rebooting the FLEXmax controller will return all the values and set points to the factory
defaults. These values are listed on page 96. It is advisable to record all custom values
before rebooting.
Figure 53 Rebooting the FLEXmax
To reboot the FLEXmax:
1. Turn off the battery and PV array circuit
breakers. The FLEXmax should have
no sources of power connected.
Observe the screen until it goes blank.
2. Press and hold the first and third soft
keys (SK1 and SK3).
3. While holding down these soft keys,
switch on the battery circuit breaker.
This process follows the power-up
sequence shown on page 17. Continue
to follow the Select Version screen
instructions from the beginning of
the manual.
DC Circuit
Breakers
SK1 and SK3