Outback FM80 User Manual
Operation
900-0009-01-00 Rev D 59
Figure 50 Secondary STATS Screen
Viewing the Firmware Revision
The current firmware revision of the FLEXmax controller can be viewed on its own screen.
Figure 51 Firmware Revision Screen
Extended Play Mode
If the MPP voltage is low enough to approach the battery voltage (usually when the PV array is
very hot), it is near the effective limit of the MPPT function. Side effects may cause the
FLEXmax components to make a squealing noise. Extended Play mode alleviates this problem
by extending the parameters of the MPPT sweep.
To activate or deactivate the Extended Play feature:
Figure 52 Extended Play Mode
Revision Screen
Follow the instructions in Figure 51
for reaching the Revision screen.
While continuing to hold SK1, press
and hold SK3. After a few seconds,
the screen will toggle the status of
Extended Play and display it.
X
on means the mode is on.
If necessary, continue to press
and hold SK3 until it reads X on.
Extended Play Screen
Revision
002.001.000
X on
To deactivate, repeat the process until the screen reads X off.
In 113.6V 0.0 A
Out 12.5V 0.0 A
0.000 kW 0.0 kWH
AUX: OFF Sleeping
Status Screen
Return to the main menu screen.
From the status screen, press the
first soft key (SK1) to open the main
menu screen.
From the main menu screen, press
and hold <EXIT> (SK1). As long
as SK1 is held, it will show a
Revision screen with the current
firmware revision of the FLEXmax.
Charger Aux Light
EQ Misc Advanced
Logging Stats
EXIT GO
Main Menu
Revision
002.001.000
Total 00000 kWH
Total 0000.0 kAH
BACK DCkWH
Secondary STATS
The Secondary Stats screen shows the total accumulated DC and
A
C kilowatt-hours and kiloamp-hours of the charge controller.
Pressing the <DCkWH> soft key switches the screen between
DC kilowatt-hours and AC kilowatt-hours.
o
DCkWH
shows the DC kilowatt-hours and should be used in a
system that is not grid-interactive.
o
ACkWH
is used with a grid-interactive system. This measure is
based on a 90% inverter efficiency (1 kWh DC= 0.9 kWh AC).
Pressing the <BACK> key three times returns to the main menu.
Total 00000 kWHAC
Total 0000.0 kAH
BACK ACkW