Outback FM80 User Manual

Operation
40 900-0009-01-00 Rev D
Diversion:Solid St (AUX Mode)
Figure 26 Setting the Diversion:Solid St AUX Mode (Part 1)
IMPORTANT
:
If using wind or hydroelectric turbines, keep
the charge controller’s diversion voltage
slightly above its Absorb and Float voltage
settings for efficient functioning.
Do not use Diversion:Solid St with a
mechanical relay. The PWM action could
cause irregular relay activity.
Diversion:Solid St requires the use of a
purely resistive load. The PWM action may
work poorly with mechanical loads.
To set the mode for Diversion:Solid St:
1. From the main menu, press <> or <> to move the to
the left of Aux.
2. Press <GO> to open the AUX MODE screen.
3. Press <NEXT> until the Diversion:Solid St mode is
displayed in the AUX MODE screen.
4. Press <MODE> to cycle through ON, OFF, or AUTO.
o ON activates the A
UX output.
o OFF deactivates the AUX output.
o AUTO controls the output according to the criteria of
the selected A
UX mode.
Continued on next page...
Charger Aux Light
EQ Misc Advanced
Logging Stats
EXIT GO
Main Menu
Charger Aux Light
EQ Misc Advanced
Logging Stats
EXIT GO
AUX MODE
Diversion:Solid St
Output: Off Off
EXIT NEXT SET MODE
<NEXT> proceeds to the
next AUX MODE screen.