In order to use the Tigo TS4-S or TS4-R-S, some communication will need to occur with the FM100,
ICS Plus, or SkyBox to initiate a rapid shutdown command and quickly shut down the devices.
Figure 7 Tigo CCA, TAP, and TS4-R-S
ICS Plus
Here is an example of how to wire the Tigo TS4-R-S with the ICS Plus system. This example uses J3 to
control the power going to the Cloud Connect Advanced (CCA) and TAP. When the RSI is turned OFF,
J3 opens opens and removes power to the CCA/TAP, which initiates a rapid shutdown event. Note that
this power is a 24-volt source that is not the BKR-CTRL-DC.
Figure 8
Example configuration of a ICS Plus system with the TS4-R-S, TAP, and CCA