FireRaptor Rapid Shutdown Specifications

Inverter Compatibility
The FireRaptor operates in the same way as an isolator/disconnect switch but is located at solar panel level. Like an isolator/
disconnect, the FireRaptor is compatible with all string inverters and does not affect their operation or performance in any way.
Fail-Safe Operation
The FireRaptor is designed for fail-safe operation ensuring that, once operated, subsequent damage to the FireRaptor (e.g. by re)
will not compromise the solar panel isolation and shutdown status. Indeed, the FireRaptor has been tested to destruction by TUV
in Germany, maintaining full zero volt isolation throughout the test procedure. A copy of the TUV test report is available to view on
our website.
Installation
The FireRaptor is easy to install, requires no set-up and is suitable for both new and retro-t installations. It is designed to shutdown
two panels or it can be mounted in single panel conguration if preferred. The diagrams below show typical two-panel installations.
The FireRaptor is manufactured using original MC4 connectors on the DC cables ensuring high quality integration and compatibility.
The Emergency Switch control cable is tted with Tyco SuperSeal connectors ensuring quick and easy (plug & play) installation.
String Inverter
=
Mobile Communication
Notification
Connection to Building Alarm
System or BMS
Only available with FRS-02 version
FRS-01 & FRS-02 (Series Connection)
NOTE: If two panel installation is used in accordance with NEC 2017, each panel must be <40V.