Alino Datasheet
OutBack Power reserves the right to make changes to the products and information contained in this document without notice.
Copyright © 2019 OutBack Power. All Rights Reserved. OutBack Power is a registered trademark of Alpha Technologies Services, Inc.
3
Electrical—Inverter
Output Voltage
230VAC 230VAC 230VAC 120VAC 220VAC 120VAC 220VAC
Frequency
50Hz ± 0.5Hz 50Hz ± 0.5Hz 50Hz ± 0.5Hz 60Hz ± 0.5Hz 60Hz ± 0.5Hz 60Hz ± 0.5Hz 60Hz ± 0.5Hz
Output Wave Form
Pure sinewave Pure sinewave Pure sinewave Pure sinewave Pure sinewave Pure sinewave Pure sinewave
Load Regulation
±2% ±2% ±2% ±2% ±2% ±2% ±2%
Output Power Factor
0.8 0.8 0.8 0.8 0.8 0.8 0.8
Peak Efficiency
>88% >90% >90% >90% >90% >90% >90%
THD (Linear Load)
<3% <3% <3% <3% <3% <3% <3%
Crest Factor
3:1 3:1 3:1 3:1 3:1 3:1 3:1
Battery Low Alarm and Indication
21.9V 43.8V 43.8V 21.9V 21.9V 43.8V 43.8V
Low Battery Load Cut-Off
21.5V 43V 43V 21.5V 21.5V 43V 43V
Load Reconnect
>25V >50V >50V >25V >25V >50V >50V
Instantaneous Power (100ms)
3600VA 7200VA 9000VA 3600VA 3600VA 7200VA 7200VA
Surge Power (0.5sec)
2400VA 4800VA 6000VA 2400VA 2400VA 4800VA 4800VA
Continuous Power Rating (25°C)
1400VA 2600VA 3300VA 1400VA 1400VA 2600VA 2600VA
Short Circuit
One retry followed by permanent shutdown: 0.1sec ON and 10sec OFF One retry followed by permanent shutdown: 0.1sec ON and 10sec OFF
Load Recovery
≤100% of nominal power output and manual reset after three retries ≤100% of nominal power output and manual reset after three retries
Overload Cut-Off
Three retries followed by permanent shutdown: 110-125% 60sec ON and 10sec
OFF, 125-150% 10sec ON and 10sec OFF, 150-200% 3sec ON and 10sec OFF, 200-300%
0.5sec ON and 10sec OFF >300% 0.1sec ON and 10sec OFF
Three retries followed by permanent shutdown: 110-125% 60sec ON and 10sec OFF, 125-150% 10sec ON and
10sec OFF, 150-200% 3sec ON and 10sec OFF, 200-300% 0.5sec ON and 10sec OFF, 300% 0.1sec ON and 10sec OFF
Alino Specifications 08/2019
Electrical—PCU
Mode of Operation
Solar/grid/priority, selectable through front panel Solar/grid/priority, selectable through front panel
Self Consumption (Sleep Mode Inactive)
<26W <45W <45W <26W <26W <45W <45W
Self Consumption(Sleep Mode Active)
<10W <10W <10W <10W <10W <10W <10W
No Load Shutdown (Sleep Mode Active,
% of Rated Full Load Current)
<3% <2% <2% <3% <3% <2% <2%
No Load Recovery Time
4sec 4sec 4sec 4sec 4sec 4sec 4sec
Mechanical
Dimensions H × W × D (mm)
670 × 350 × 150 670 × 350 × 150 670 × 350 × 150 670 × 350 × 150 670 × 350 × 150 670 × 350 × 150 670 × 350 × 150
Net Weight (kg)
25 30 30 25 25 30 30
Recommended Mounting
Wall-mount Wall-mount Wall-mount Wall-mount Wall-mount Wall-mount Wall-mount
Cable Entry
Bottom Bottom Bottom Bottom Bottom Bottom Bottom
AC Input Terminals
MCB and DIN Rail feed-through terminal block 6U MCB and DIN Rail feed-through terminal block 6U
AC Output Terminals
DIN Rail feed-through terminal block 6U DIN Rail feed-through terminal block 6U
Panel Terminals
DIN Rail feed-through terminal block 10U DIN Rail feed-through terminal block 10U
Battery Terminals
DIN Rail feed-through terminal block 35U DIN Rail feed-through terminal block 35U
Environmental
Operating Temperature
0 to 50°C 0 to 50°C 0 to 50°C 0 to 50°C 0 to 50°C 0 to 50°C 0 to 50°C
Acoustic Noise
<56dB <56dB <56dB <56dB <56dB <56dB <56dB
Relative Humidity Range (Non-Condensing)
5 to 95% 5 to 95% 5 to 95% 5 to 95% 5 to 95% 5 to 95% 5 to 95%
Altitude
2000m above sea level 2000m above sea level 2000m above sea level 2000m above sea level 2000m above sea level 2000m above sea level 2000m above sea level
Operating Environment
Indoor/protected Indoor/protected Indoor/protected Indoor/protected Indoor/protected Indoor/protected Indoor/protected
Ingress Protection
IP21 IP21 IP21 IP21 IP21 IP21 IP21
50Hz 60Hz
Models:
APCU 1424 APCU 2648 APCU 3348 APCU 1424A APCU 1424B APCU 2648A APCU 2648B
www.outbackpower.com
#980-00074-01-001 REV A