Temperature Derating
All FXR inverters can deliver their full rated wattage at temperatures up to 25°C (77°F). The FXR
maximum wattage is rated less in higher temperatures. Above 25°C, each inverter model is derated by
a factor of 1% of that model’s rated wattage for every increase of 1°C. This derating applies to all
power conversion functions (inverting, charging, selling, offsetting, etc.)
Figure 20 is a graph of wattage over temperature, showing the decrease in rated wattage with
increased temperature. The graph ends at 50°C (122°F) because the FXR inverter is not rated for
operation above that temperature.
Figure 20 Temperature Derating
Regulatory Specifications
Certifications
This product has been certified by ETL to meet the following standards:
IEC 62109-1:2010 and IEC 62109-2:2011 — Safety of Power Converters for use in Photovoltaic Systems
Models FXR2024E, VFXR3024E, FXR2348E, and VFXR3048E
are certified to the following:
AS4777.2 and AS4777.3 — Grid Connection of Energy Systems
via Inverters
Output Watts
VFXR3024E and VFXR3048E
VFXR2612E
FXR2348E
FXR2024E and FXR2012E
3000
2000
1500
10°C
50°F
20°C
68°F
30°C
86°F
40°C
104°F
50°C
122°F
0
25°C
77°F
1950
2250
1725
2500
13