OutBack Power Serial Communications Guide
Mate Serial Communication Guide         Copyright 2007 © OutBack Power Systems, Inc.  
     19009 62
nd
 Ave NE, Arlington WA 98223 USA 
 Page 17 of 20  Rev 4.04 10/21/08   Tel 360 435 6030 Fax 360 435 6019 
Extra data identifier: ‘00’ to ‘99’, this is an ASCII expression of a 8 bit byte with bits 1 through 7 being 
used. 
Bit: 7  extra data numeric sign 
0: positive value 
1: negative value 
Bits: 1-6 
  0:  Accumulated AH shunt ‘A’ 
  1:  Accumulated kWH shunt ‘A’ 
  2:  Accumulated AH shunt ‘B’ 
  3:  Accumulated kWH shunt ‘B’ 
  4:  Accumulated AH shunt ‘C’ 
  5:  Accumulated kWH shunt ‘C’ 
  6:  Days since full 
  7:  Today’s minimum SOC 
8:  Today’s net input AH 
9:  Today’s net output AH 
10.  Today’s net input kWH 
11:  Today’s net output KWH 
  12:  *Charge factor corrected Net battery AH 
  13:  *Charge factor corrected Net battery kWH 
 14-35 Reserved  
  kWH values: ‘00000’ to ‘65535’, 000.00 to 655.35 Kwatts 
  AH values: ‘00000’ to ‘65535’, 0 to 65535 
  Days since full output: ‘00000’ to ‘09999’, 0.0 to 999.9 
  Minimum SOC output: ‘00000’ to ‘00100’, 0 to 100 percent 
  *MATE version 4.04 and above 
FLEXnet DC battery voltage: ‘000’ to ‘999’, A 24.8 Vdc battery voltage will be sent as ‘248’. 