OutBack Power MATE Series Overview

FLEXnet DC
900-0131-01-00 Rev A.vsd\FNDC\2012-03-21
©2012 OutBack Power Technologies. All Rights Reserved.
Page 9
Main Screen
MAIN----------------
3:02:14P
SUM STATUS SETUP ADV
E -------------- F
Battery Discharging
State of Charge 100%
DC Now 25.4V 100%
IN 0.4A 0.010kW
OUT 1.6A 0.040kW
BAT -1.2A -0.030kW
DC Today minSOC 97%
In 247AH 12.84kWH
Out 240AH 12.50kWH
Bat 7AH 0.34kWH
DC BAT 25.4V 100%
Bat -0.3A -0.010kW
Net 0.4AH 0.00kWH
Days Since Full 1.1
FX Total 25.4V 97%
Inverting 0.000kW
AC Loads 0.000kW
Buying $ 0.000kW
State-of-Charge Screen
Summary Screen #1
Summary Screen #2
Summary Screen #3
Summary Screen #4
Press this soft key to
proceed. This screen will
also automatically move
forward after a user-
defined period of time.
1
1
1
1
STATUS------------------
choose device:
FX CC DC MAIN
MAIN--------------------
3:02:14P
SUM STATUS SETUP ADV
Main Screen
NOTE: The values shown in this illustration will
vary depending on the model of inverter.
STATUS/DC/PAGE 1-------
STATS
METER SHUNT BATT PG2
A: 0.1 A 0.001 kW
B: 0.0 A 0.000 kW
C: 0.0 A 0.000 kW
DOWN STATUS
A: -1 Ah 0.100 kWH
B: 0 Ah 0.000 kWH
C: 0 Ah 0.000 kWH
DOWN UP TOP
METER/DC/SHUNT A
removed
12 AH 0.16 kWH
DOWN UP TOP
METER/DC/SHUNT A
charged
12 AH 0.16 kWH
DOWN UP TOP
STATUS/DC/SHUNT A
max removed
amps 0.9
DOWN UP RESET TOP
STATUS/DC/SHUNT A
max removed
kWatts 0.010
DOWN UP RESET TOP
STATUS/DC/SHUNT A
max charged
amps 10.1
DOWN UP RESET TOP
STATUS/DC/SHUNT A
max charged
kWatts 0.129
DOWN UP RESET TOP
STATUS/DC/SHUNT B
max removed
amps 0
DOWN UP RESET TOP
STATUS/DC/SHUNT B
max charged
amps 30.2
DOWN UP RESET TOP
STATUS/DC/SHUNT B
max charged
kWatts 2.040
DOWN UP RESET TOP
STATUS/DC/BATT
total days at 100%
0.5
DOWN UP RESET TOP
STATUS/DC/BATT
days since charge
parameters met 5.9
DOWN UP TOP
STATUS/DC/BATT
battery min today
24.8 Vdc
DOWN UP RESET TOP
STATUS/DC/SHUNT B
max charged
amps 39.8
DOWN UP RESET TOP
METER/DC/SHUNT B
removed
0 AH 0 kWH
DOWN UP TOP
METER/DC/SHUNT B
charged
12 AH 0.16 kWH
DOWN UP TOP
METER/FN/METER
DC firmware revision
000.00/040
DOWN UP TOP
STATUS/DC/SHUNT
end of shunt
status menu
UP TOP STATUS
STATUS/DC/BATT
battery max today
25.4 Vdc
DOWN UP RESET TOP
STATUS/DC/BATT
temp compd batt
setpoint 28.4 Vdc
DOWN UP TOP
STATUS/DC/BATT
system battery
temperature 29°C
DOWN UP TOP
STATUS/DC/BATT
cycle charge
factor 78%
DOWN UP TOP
STATUS/DC/BATT
cycle kWhr charge
efficiency 65%
DOWN UP TOP
STATUS/DC/BATT
lifetime kAH removed 5
DOWN UP RESET TOP
STATUS/DC/BATT
end of battery
status menu
UP TOP STATUS
METER/FN/METER
end of meter menu
UP TOP STATUS
STATUS/DC/SHUNT C
max removed
amps 0
DOWN UP RESET TOP
STATUS/DC/SHUNT C
max charged
amps 30.2
DOWN UP RESET TOP
STATUS/DC/SHUNT C
max charged
kWatts 2.040
DOWN UP RESET TOP
STATUS/DC/SHUNT C
max charged
amps 39.8
DOWN UP RESET TOP
METER/DC/SHUNT C
removed
0 AH 0 kWH
DOWN UP TOP
METER/DC/SHUNT C
charged
0 AH 0.00 kWH
DOWN UP TOP
STATUS/DC/PAGE2--------
PG1 AUX MAIN
STATUS/DC/AUX---------
aux control
manual
DOWN STATUS
STATUS/DC/PAGE2-------
aux relay state: OFF
UP STATUS
These screens are informational
only. No changes can be made
from this location in the Menu Map.
MAIN-------------------
3:02:14P
SUM STATUS SETUP ADV
To return to the Main
screen at any time:
Press and hold the 2 left soft keys at the same
time. Release when the Main screen appears.